C172R memory items Flashcards

1
Q

ENGINE FAILURE DURING TAKEOFF ROLL

A
  1. Throttle – IDLE.
  2. Brakes– APPLY.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

ENGINE FAILURE IMMEDIATELY AFTER TAKEOFF

A

Airspeed – 65 KIAS (flaps UP).
60 KIAS (flaps DOWN).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ENGINE FAILURE DURING FLIGHT (Restart Procedures)

A
  1. Airspeed – 65 KIAS.
  2. Fuel Shutoff Valve – ON (push full in).
  3. Fuel Selector Valve – BOTH.
  4. Auxiliary Fuel Pump Switch – ON.
  5. Mixture – RICH (if restart has not occurred).
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

FIRE DURING START ON GROUND

A

Ignition Switch – START, Continue Cranking

If engine fails to start:
4. Throttle – FULL OPEN.
5. Mixture – IDLE CUT OFF.
6. Cranking – CONTINUE.
7. Fuel Shutoff Valve – OFF (Pull Full Out).
8. Auxiliary Fuel Pump – OFF.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ENGINE FIRE IN FLIGHT

A
  1. Mixture – IDLE CUT OFF.
  2. Fuel Shutoff Valve – OFF (Pull Full Out).
  3. Auxiliary Fuel Pump Switch – OFF.
  4. Master Switch – OFF.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

ELECTRICAL FIRE IN FLIGHT

A
  1. Master Switch – OFF.
  2. Vents, Cabin Air, Heat – CLOSED.
  3. Fire Extinguisher – ACTIVATE
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

CABIN FIRE

A
  1. Master Switch – OFF.
  2. Vents/Cabin Air/Heat – CLOSED (to avoid drafts).
  3. Fire Extinguisher – ACTIVATE
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

WING FIRE

A
  1. Landing/Taxi Light Switches – OFF.
  2. Navigation Light Switch – OFF.
  3. Strobe Light Switch – OFF.
  4. Pitot Heat Switch – OFF.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

INADVERTENT ICING ENCOUNTER

A
  1. Turn pitot heat switch ON.
  2. Turn back or change altitude
  3. Pull cabin heat control full out and open defroster outlets
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

STATIC SOURCE BLOCKAGE
(Erroneous Instrument Reading Suspected)

A
  1. Static Pressure Alternate Source Valve – PULL ON.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly