Buttons And Switches Flashcards

1
Q

What connect the DC service bus to the APU battery direct bus?

A

DC service switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What happens when you turn the battery master on?

A

Connect / disconnects APU and main battery direct busses to battery busses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

AC button

A

Selects AC Power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What does the green AVAIL light mean?

A

External Electrical power is available and ready to use. Correct phase voltage and frequency.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does the IN USE light mean on the AC power button?

A

External power is supplying power to the AC busses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens when you push the IDG 1 or 2 switch lights?

A

The respective IDG is separated from the accessory gearbox. The white IDG light will illuminate.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What does illumination of the Amber fault light mean on the IDG switch light?

A

High oil temperature or low oil pressure is detected in the IDG. (HOT LOP)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What happens when you press the AC ESS XFER button?

A

It illuminates and manually transfers the AC ESS BUS from AC BUSS 1 to AC BUSS 2.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Will the AC ESS XFER automatically transfer?

A

Yes, if a fault is detected on AC BUS 1 it will automatically transfer illumination of the switch light.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What do the GEN switches in AUTO do?

A

Connect the respective generator to its appropriate BUS provided the generator is functioning properly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What does GEN switch in OFF / RESET do?

A

Disconnects the generator from its bus and rearms the generator control circuit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Auto transfer buttons on the IDG panel?

A

Disables automatic transfer of associated IDG

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Amber AUTO XFER Fail light?

A

Fault or overcurrent situation has occurred and respective BUS has been isolated preventing auto transfer.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Left and Right Hydraulic Shutoff buttons?

A

Manually closes the hydraulic shutoff valves. Isolates the engine driven pump from the associated hydraulic reservoir. The white light indicates SOV Closed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Hydraulic switches in AUTO Mode?

A

Automatically operates the pump when any generator online and the Flaps greater than zero

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

At what psi do the hydraulic pumps operate?

A

3000 psi

17
Q

What kind of hydraulic fluid do we use?

A

Skydrol (purple color)

18
Q

If hydraulic pump 1A or 2 A fails, will the respective electric pump activate automatically?

A

No

19
Q

Which hydraulic systems are actively cooled?

A

Hydraulic systems 1 and 2

20
Q

If there is an engine driven hydraulic pump problem , 1A or 2A , is the associated engine required to be shut down?

A

No, a shutoff valve is positioned between the pump and the reservoir to isolate the pump from the system

21
Q

What do the left or right engine START push buttons do?

A

Starts / Stops the engine start sequence

22
Q

What does the CONT Ignition switch light do?

A

Selects continuous ignition of both igniters on both engines . Both A and B igniters fire continuously. The switch light will illuminate.

23
Q

When will the CONT switch light illuminate and the igniters fire automatically?

A

FADEC senses a flameout
Just prior to stickshaker during a stall
Airflow is disrupted thru the engine

24
Q

What does the APU PWR FUEL button do when pressed?

A

APU fuel pump is energized
ECU powers up
An APU IN BITE status message appears on ED 2
APU RPM and EGT gauges appear on ED 2
The door opens when on the ground
The APU fuel shutoff valve opens

25
Q

What does the APU PWR FUEL button do? (Short answer)

A

Energizes APU fuel pump and opens APU fuel shutoff valve. Accompanied by APU IN BITE message?

26
Q

APU START STOP switch pushed in?

A

In flight the APU door with modulate open as needed
The Starter motor is energized
The White start light illuminates
At 46 to 60 % RPM the START light extinguishes
At 99% RPM + two seconds the green AVAIL light illuminates

27
Q

APU Start/Stop switch pushed out?

A

Fuel shutoff valve closes
The APU shuts down
The green AVAIL light extinguishes
The inlet door closes

28
Q

APU START/ STOP button? (Short answer)

A

1st push. Starts motor

2nd push. 1. Closes fuel shut off valve
2. Extinguishes AVAIL light
3. Closes air inlet door

29
Q

What is the primary purpose of the APU?

A

Provide electrical power