Fire blocking shall be installed horizontally at intervals not exceeding _____ feet.
10
Fireblocking shall consist of the following materials:
1) 2” nominal lumber.
2) Two pieces of 1” nominal lumber with broken joint laps.
3) 3/4” wood structural panels with joints backed by 23/32” wood structures panels.
4) 3/4” particleboard with joints backed by 3/4” particle board.
5) 1/2” gypsum board.
6) 1/4” cement-based millboard.
7) Batts or blankets of mineral wool or glass fiber or other approved materials installed in such a manner as to be securely retained in place.
8) Cellulose insulation as tested in accordance with ASTM E119 or UL 263, for the specific application.
In combustible construction where there is usable space both above and below the concealed space of floor-ceiling assembly ______ shall be installed so that the area of the concealed space does not exceed ________.
draftstops
1000sqft
Draftstopping materials shall be not less than __ gypsum board, ___ wood structural panels or other approved materials adequately supported.
1/2”
3/8”
Bathrooms, water closet compartments or other similar rooms shall be provided with aggregate glazing area in window of not less than ___ , one-half of which shall be openable. Unless ____ ____ and a local _____ system are provided.
artificial light
exhaust
Air intake openings shall be located not less than ____ from any hazardous or noxious contaminant, such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks. The exhaust from toilet rooms, bathrooms and kitchens shall not be considered hazardous or noxious. This isn’t required where the intake opening is located _____ or greater ______ the contaminant source.
10’
3’
below
Exhaust are shall not be directed onto ______.
walkways
Air exhaust and intake openings that terminate outdoors shall be protected with corrosive-resistant screens having and opening size of not less than _____ and a maximum opening size of ______.
1/4”
1/2”
Exterior stairways shall be provided with an artificial light source located at the _____.
top landing
Habitable rooms shall have a floor area of not less than _____. Except kitchens.
70sqft
Habitable rooms shall be not less than _____ in any horizontal dimension. Except kitchens.
7’
Habitable space, hallways and portions of basements containing these spaces shall have a ceiling height of not less than ____. Bathrooms, toilet rooms and laundry rooms shall have a ceiling height of not less than _______. (There are exceptions)
7’
6’-8”
Toilets shall have a minimum of ____ clearance to either side measured from center of toilet and a minimum of ____ in front measured from the front of the toilet.
15”
21”
A vanity sink shall have a minimum ____ clearance in front of it.
21”
Showers shall have a minimum _____ clearance in front of opening.
24”