Building Level III Flashcards
What is the minimum type of construction allowed for a Group B Occupancy with the highest occupied floor 100 feet above the lowest level of Fire Department Access?
Type II
What is the maximum travel distance to an exit in a S-2 sprinkled, Type V Building.
400 feet
What is the minimum fire resistance rating for a door into a stairway located on the floor of a Type I building.
1.5 hours
What is the maximum height of a penthouse located on a Type I building?
No limit
Stages do not require fire sprinklers when the square footage is ______?
1000 sq ft or less in area and 50ft or less in height. 410.6.2
Stairways that are required to have an area of rescue assistance within the stairway must be a minimum of _____ inches in the clear between the handrails.
48 inches
The height and area of a building are determined by ______ .
Type of Construction and Occupancy
Motor fuel dispensing facilities are of what occpancy classification?
Group M
Indoor swimming pools without spectator seating are considered _______ Occupancy?
A-4
Boiler rooms in public schools must be separated from the rest of the structure by ________ hour rated construction.
2 hour
Which of the following is the most fire resistant?
Type I
The maximum unsprinklered fire area in Group E shall not exceed _______ square feet?
12,000 sqft
Exit access corridors, when required to be rated in unsprinkled buildings, shall have a rating of not less than ______ hours.
1 hour
Standpipes are required to be installed in accordance with what standard?
NFPA 14
The minimum width of a mall in a structure shall not be less than ______ feet.
20 feet
Class A materials have a flame spread rating of ______.
0-25
In classrooms, the area allowance per occupant is _____.
20 net
Exit stairways designed to accomodate 372 persons in a sprinkled Group B; Business occupancy must be at least ______ inches in width.
55.8 inches
Standby power is required for covered mall buildings exceeding ______ square feet.
50,000 sq ft
In a Group I - 3 Occupancy, Use Condition 1 facilities are permitted to be constructed as Group _____.
R-3
The numbers of occupants in Assembly Occupancies utilizing tables and chairs are computed at a rate of one occupant per ______ net square feet.
15 feet
Classrooms are designed for a uniformly distributed live load of ________ pounds per square feet.
40 lbs
To be considered high-rise buildings the highest occupied floor must be at least _______ above the lowest level of fire department vehicle access.
75 feet
Without exception, the maximum height of a Group M Type III - A structure is _____ feet.
65 ft
Wind exposure category B is described by which of the following?
Urban and suburban areas.
When determining the adequate thickness of sprayed on fire resistance the inspector must take _______ measurements per 1000 square feet.
4 locations.
When considering wind pressures on exterior masonry walls for enclosed structures in 100 MPH wind zones, the maximum height to thickness ratio for 8 inch hollow masonry units is ________.
14
Woodworking operations exceeding ______ square feet, which generate finely divided combustible waste, are required to be sprinklered.
2500 sq ft.
Horizontal exits shall have a fire resistance rating of not more than _______ hours.
2 hours