Building Flashcards
Code
The purpose of this code is to establish _____________ requirements to safeguard the public safety, health and general welfare.
minimum
Code
Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most ________________ shall govern.
restrictive
Code
Where a referenced code or standard includes subject matter that is within the scope of the IRC, the provisions of the ____________ shall take precedence.
IRC
Code
An alternative material or method shall be approved where the proposed design is ____________ and complies with the ____________ of the code.
satisfactory
intent
Code
Compliance with the specific ____________-based provisions of the International Codes in lieu of specific requirements of the IRC shall be permitted as an alternative.
performance
Code
A permit is not required for one-story detached accessory structures provided that the floor area does not exceed __________ square feet.
200
Code
Fences that are ___________ feet or less in height do not required permits.
7
True/False
A permit is not required for the replacement of branch circuit overcurrent devices (breakers) of the required capacity in the same location (within a panel).
True
Code
Unattached decks not exceeding __________ square feet in area, that are not more than __________ inches above grade do not require a permit.
200
30
(Provided the decks do not serve the exit door required by Section R311.4.)
Code
Where equipment replacements and repairs must be performed in an emergency situation, the permit application shall be submitted within the _______ _________ business day.
next working
…to the building official.
Code
An application for a permit for any proposed work shall be deemed to have been abandoned ________ days after the date of filing.
180
180 days also applies to extensions)
Code
Before issuing a permit, the building official is _________ to examine or cause to be examined buildings, structures, and sites for which an application has been filed.
authorized
Code
When the building official issues a permit, the construction documents shall be approved in writing or by a stamp which states __________ __________ __________ __________.
REVIEWED FOR CODE COMPLIANCE
Code
Final inspection shall be made after the permitted work is ____________ and prior to ______________.
complete
occupancy
Code
If located in a flood hazard area, the documentation of elevations required in Section R322.1.10 shall be submitted to the building official prior to the ______________ inspection.
final
Definition
Signifies access that requires the removal of an access panel or similar removable obstruction.
Accessible
Readily Accessible signifies access without the necessity for removing a panel or similar obstruction.
Definition
A finished or unfinished area, not considered a story, where the occupiable space is enclosed by the roof assembly above and the floor-ceiling assembly below is a __________.
habitable attic
Other conditions relating to occupiable floor area must also be met.
Definition
Hot Water is water at a temperature greater than or equal to _______ degrees F.
110
Definition
A wall supporting any vertical load in addition to its own weight is a __________-_______________ wall.
load-bearing
Question
What is the minimum uniformly distributed live load for habitable attics and attics served with fixed stairs?
30 pounds per square foot
Review of tables will be useful as knowledge of many tables is necessary for the exam.
Code
Wood structural panels with a minimum thickness of __________ inch and a maximum span of __________ feet shall be permitted for opening protection in windborne debris regions.
7/16
8
Code
The seismic provisions of the IRC apply to detached one- and two-family dwellings in Seismic Design Categories __________.
D0, D1, and D2
Table
For dwellings with fire sprinkler systems, exterior walls with a fire separation distance less than ______ feet shall have not less than a one-hour fire-resistive rating with exposure from the outside.
3
See Note for subdivisions where all dwellings are sprinklered.
Table
In a nonsprinklered townhouse building, the common wall between units shall be a minimum ________ -hour ________-________ ________.
2
fire-resistance rated
(A minimum 1-hour rated wall is required where the building is sprinklered.)
Code
For townhouse separation, a parapet is not required when the roof sheathing is fire-retardant-treated wood for a distance of _______ feet on each side of the wall and there are no penetrations in the roof within ________ feet of the wall.
4
4
Code
Openings from a private garage directly into a room used for ________ ________ shall not be permitted.
sleeping purposes
Code
Doors between the garage and residence shall be equipped with a __________ ___________.
self-closing device
Table
Garages shall be separated from residence and attics by not less than ______-inch gypsum board or equivalent applied to the garage side.
1/2
Review and know this table.
Code
Enclosed accessible space under stairs shall have walls, under-stair surface and any soffits protected on the enclosed side with _________ -inch gypsum board.
1/2
Code
Wall and ceiling finishes shall have a flame spread index of not greater than ________.
200