Brachytherapy Sources Flashcards

1
Q

What are the physical characterisitics of Ra-226?

A

Half Life : 1600 yr

Photon energy: 0.047-2.45 MeV (0.83 avg)

Half Value Layer: 12.0 mm lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the physical characteristics of Rn-222?

A

Half Life : 3.83 days

Photon energy: 0.047-2.45 MeV (0.83 avg)

Half Value Layer: 12.0 mm lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the physical characterisitics of Co-60?

A

Half Life : 5.26 yr ( 1 % / month )

Photon energy: 1.17, 1.33 MeV

Half Value Layer: 11.0 mm lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the physical characteristics of Cs-137?

A

Half Life : 30 yr ( 2 % / year)

Photon energy: 0.662 MeV

Half Value Layer: 5.5 mm lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the physical characterisitics of Ir-192?

A

Half Life : 73.8 days ( 1 % / day )

Photon energy: 0.136-1.06 MeV (0.38 avg)

Half Value Layer: 2.5 mm lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the physical characterisitics of Au-198?

A

Half Life : 2.7 days

Photon energy: 0.412 MeV

Half Value Layer: 2.5 mm lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the physical characterisitics of Pd-103?

A

Half Life : 17.0 days (4 % / day)

Photon energy: 0.021 MeV avg

Half Value Layer: 0.008 mm lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the physical characterisitics of I-125?

A

Half Life : 59.4 days (1 % / day)

Photon energy: 0.028 MeV avg

Half Value Layer: 0.025 mm lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What sources are smallest energy and normally used interstitially?

A

I-125

Pd-103

Cs-137

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which brachy sources have higher energy photons?

A

Co-60

Cs-137

Ir-192

How well did you know this?
1
Not at all
2
3
4
5
Perfectly