Chapter 6 Basic Fittings for Hot Water Boilers
The automatic fill valve is a _____ valve which keeps the system filled with water and maintains a set pressure in the system.
Select one:
A. Temperature control valve
B. Pressure control valve
C. Back pressure valve
D. Pressure reducing valve
E. Air vent valve
D. Pressure reducing valve
The temperature of the water in a hot water heating system with an open expansion tank is normally limited to:
Select one:
A. 99°C (210°F)
B. 60°C (140°F)
C. 150°C (302°F)
D. 80°C (175°F)
E. 121°C (250°F)
D. 80°C (175°F)
The relief valve on hot water boilers with a working pressure of up to 414 kPa (60 psi) should open with in a variation of _____ below or above the setpoint.
Select one:
A. 20 kPa (3 psi)
B. 30 kPa (4.5 psi)
C. 10 kPa (1.5 psi)
D. 14%
E. 5%
A. 20 kPa (3 psi)
The discharge piping from the relief valve should be piped to a safe point for disposal and can be:
Select one:
A. Terminated above a floor drain
B. Connected to the deaerator
C. Connected to the condensate tank
D. Connected to any drain
E. Connected to any vent
A. Terminated above a floor drain
The wax filled sensor probe in a combination pressure-temperature relief valve will expand and open the valve by means of a piston at approximately:
Select one:
A. 99°C (210°F)
B. 50°C (122°F)
C. 60°C (140°F)
D. 110°C (230°F)
E. 134°C (273°F)
A. 99°C (210°F)
The purpose of the expansion tank in a hot water heating system is to:
Select one:
A. Provide space to store the returning condensate
B. Add make-up water to the system
C. Provide storage space for excess water
D. Separate the water and steam produced
E. Provide storage space for excess steam
C. Provide storage space for excess water
The highest pressure to which the scale on the pressure gauge of a hot water boiler may be graduated is _____ times the pressure at which the pressure relief valve is set.
Select one:
A. 2
B. 1.5
C. 2.5
D. 3
E. 3.5
E. 3.5
The operating handle of the valve to the pressure gage on a hot water boiler must be of the:
Select one:
A. Diaphragm type
B. Solenoid type
C. Hand wheel type
D. Tee or lever handle design
E. A valve is not permitted in this location
D. Tee or lever handle design
On a hot water boiler, the highest value on the graduated scale of the pressure gauge shall not be less than _____ times the pressure at which the pressure relief valve is set..
Select one:
A. 3.5
B. 3
C. 2.5
D. 1.5
E. 2
D. 1.5
The minimum size of the hot water heating boiler bottom blow off or drain connection shall be:
Select one:
A. 25 mm (1 in.)
B. 6 mm (¼ in.)
C. 75 mm (3 in.)
D. 19 mm (¾ in.)
E. 15 mm (½ in.)
D. 19 mm (¾ in.)
The pressure relief valve is typically installed on the boiler or reasonably close to the boiler outlet with:
Select one:
A. A plug valve for isolation
B. A globe valve for isolation
C. A ball valve for isolation
D. No valve between
E. A gate valve for isolation
D. No valve between