Book 84- Field Operations Guide Flashcards

Fire Prevention

1
Q

A alarm assignment is how many companies

A

no less than 4 companies
-no less than 1 truck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A alarm required flow gpm

A

less than 4500gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

category B assignment companies

A

no less than 6 companies
-no less than 2 trucks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

B assignment required gpm flow

A

4500 gpm and above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Category B assignment dwelling types

A

-4 stories or more
-commercials over 15,000sqft with 1 roof and two floors
-commercials over 10,000sqft with 1 roof and 1 floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

what category B assignment dwelling types fall under FPB for Public Safety Sector

A

-schools, nurseries 2 or more stories
homes for aged, hospitals, public assemblages, churches except B-2 under 100ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Category C companies

A

no less than 4 companies
-one truck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

what are Category C assignments for

A

special assignments
-brush, harbor, airport

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

what 4 things do automatic alarms include

A

-waterflow
-bells ringing
-smoke detectors
-manual pulls

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

if more than 1 automatic device is activated on automatic alarm, who gets dispatched

A

full assignment or additional resources will be attached

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

the standard used to estimate number of companies to extinguish fully involved structure is based on ____ gpm per line and two lines per company

A

250gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

what are the types of ems responses

A

BLS- non emergency
BLS -emergency
ALS- non high risk
ALS- high risk

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

ALS high risk has what resources responding

A

Closest resource and ALS rescue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

to have a first alarm assignment change, you must forward 1 copy to who and have clear justification for request

A

Bureau commander and Bureau of Emergency services

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

what are the 4 responsibilities of command

A

1- rescue endangered occupants and treat injured
2- stabilize incident
3- conserve property
-provide for safety and accountability of personnel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

what are the first 4 steps of IC

A

-size up
-assume command
-control comms
-identify incident action plan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

transfer of command is for what

A

improve quality of ICS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

what two ways can the transfer of command happen through

A

face to face
-radio

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

True or False: when transfer of command happens, it shall be announced

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

what is the order of steps from intial assignment to greater emergency expanded

A

Initial Assignment
Greater Alarm
Major Emergecny
Major Emergency Expanded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

what resources does a brush dispatch consist of

A

-1 task force
-4 engines
-2 helicopters
-2 battalion chiefs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

what is a battalion chief responsible for in a emergency

A

Abatement of the emergency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

when will and EMS capatin be attached to an incident

A

when there are:
-3 or more rescue ambulances
or
-2 or more paramedic ambulances

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

what is defined as “incident that includes more companies than defined in first alarm assignment and less companies than defined by major emergency”

A

greater alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

what chiefs will be dispatched to greater alarms

A

division commander and second battalion chief

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

when more than how many companies will a chief be dispatched as a safety officer

A

more than 10 companies

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

how many companies will make an incident a major emergency

A

15 or more companies

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

the LAFD Incident management team is made up of how many on call members

A

12 members

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

there are 3 levels of activation for IMTS. How many members for each activation level

A

Level 1: 4
Level 2: 7
Level 3: 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

who maintains on call roster for IMTS

A

metro

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

incident names should be how many syllables

A

one or two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

Metro will update IC with incident clock at what time intervals starting when first dispatched unit arrives on scene

A

15 minute intervals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

are divisions specific functions or geographical

A

geographic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

are groups functions or geographical

A

specific functions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

what are branches used for

A

multiple groups or divisions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

what does planning section do

A

gathers, analyzes, processes info needed for effective decsion making

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

what is the objective of fire preventions

A

allow for uniform application of Los Angeles City Fire Code throughout city

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

when shall a drive through inspection be done and forwarded to battalion commander

A

every Calendar quarter (3 months)
-forwarded within 10 days of each inspection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

what is a drive through inspection meant for

A

identify hazardous conditions and new multi unit dwellings (16 units or more) in framing stages

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

what amount of inspections shall be completed each calendar month to allow for interruptions

A

1/10th of total inspection load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

who has the authority to adjust inspection work load

A

Battalion commanders

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

whos responsibility is it to inspect new construction including major additions or remodeling

A

Fire Prevention Bureau

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

fire station personnel can inspect new construction on apartments 2 stories or less with _____ or less units

A

15 dwelling units or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
44
Q

fire station personnel can inspect new construction on hotels 2 stories or less with _____ or less units

A

19 guest rooms or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
45
Q

What is group A occupancy

A

occupant load of 100 or more people

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
46
Q

Can fires station personnel inspect Group A

A

no, except churches under 750 occupant load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
47
Q

FPB will inspect what Group B occupancies

A

-4 stories or more
-40,000 sqft or more total area
-divison 4 permit required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
48
Q

What are Group B exceptions that fire station personnel can inspect

A

except group A with less than 99 person load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
49
Q

what other groups can FPB inspect

A

E, H (except repair garages), I, R (6 stories or more),

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
50
Q

what Group A occupancies will station personnel inspect

A

occupant load less than 100 people
-church less than 750

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
51
Q

what Group B occupancies will station personnel inspect

A

-less than 4 stories
-less than 40,000 sqft total

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
52
Q

what Group H occupancies will station personnel inspect

A

repair garages

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
53
Q

what Group R occupancies will station personnel inspect

A

-division 1 occupancies less than 6 stories
-division 3
-occupancies 6 or less non ambulatory persons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
54
Q

outpatient medical clinic fire clearances will be handled by who

A

FPB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
55
Q

F-340C is for what

A

Fire/Life safety notice for clearance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
56
Q

what occupancies require annual inspections

A

occupancies that require more than 1 exit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
57
Q

what occupancies require inspections every 3 years

A

occupancies that only require one exit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
58
Q

what occupancies require day/ night inspections twice a year, 6 months apart

A

-apartments with 16 or more units/ 3-5 stories in height

-enclosed hotels 20 or more guest rooms/ 3-5 stories in height

-company assemblage (99 or less occupants)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
59
Q

what apartments/ hotels shall be inspected once a year

A

-garden style apartments 16 or more units/3-5 stories

-non enclosed corridor style hotels 20 or more guest rooms/ 3-5 stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
60
Q

what multi unit dwellings shall be inspected once every 3 years

A

-residential occupancies 5-15 units/ less than 3 stories
-hotels 6-19 guest rooms/ less than 3 stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
61
Q

when do dwelling occupancies of 4 or less units get inspected

A

by request or complaint

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
62
Q

who inspects brush and grass

A

brush task force or department sweep

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
63
Q

when do platoons switch inspection responsibilities

A

once every 3 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
64
Q

A-1 vs A-1 group occupancy

A

More than 1000 person load vs less than with stage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
65
Q

what form to transfer inspections to FPB

A

F-44

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
66
Q

what is fire prevention complaint form

A

F-334

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
67
Q

what is the Basic Inspection Guide Book number

A

Book 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
68
Q

what maps are used for F-1308 and F-340 legal descriptions

A

Assessor Maps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
69
Q

when do you put “closed no visible hazards” in notes on FPOS

A

after two attempts and a phone call to occupancy with no answer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
70
Q

if you are unable to make contact with business after 2 attempts and call and property visually needs inspection, who can you receivelegal liason the contact information from to mail F-340C

A

legal liason unit or brush unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
71
Q

if after 30 days of attempts and contacts were unsuccessful, forward property to FPU, _____

A

legal liason

72
Q

how shall F-340A,B,C, D notices be made

A

by mail or in person

73
Q

what form is served indicating need for tests required

A

F-340D

74
Q

installation, alteration, repair of fire protective system is what form

A

F-338

75
Q

if after ____ days an inspection compliance has not been obtained, forward Request for legal action F-290 to Legal Liason Unit

A

30 days

76
Q

what is F-336

A

condemnation tag

77
Q

minimum age of witness to testify in court

A

14

78
Q

how many citation books per battalion and station

A

1

79
Q

parking within _____ ft of fire station driveway leaving vehicle unattended is a parking violation

A

15ft

80
Q

parking within ____ of a hydrant is a parking violation

A

15ft

81
Q

hazardous material inventory inspections shall be done how often

A

3 years

82
Q

what is BP-8

A

hazardous material form

83
Q

how many copies need to be made when a notice is written to a city building

A

1 original, 3 copies

1 copy to station
1 copy to FPB
1 copy to general services

84
Q

can you write notices to a federal building

A

no

85
Q

what is F-44

A

Intradepartmental Memorandom

86
Q

seating capacity based on square foot

A

15 sqft per person

87
Q

how many sqft per person on dancefloor

A

7 sqft

88
Q

1 exit has max occupancy of

A

49 people

89
Q

doors must open outwards if occupancy is over

A

50 people

90
Q

f-225 shall be forwarded from fire personnel that assist in overcrowding count within _____ hours

A

48

91
Q

drums or carboys may not be stacked more than _____ unless on pallet

A

two containers high

92
Q

drums can be stacked up to ____ ft on pallets, but may not extend passed width of pallet

A

12 ft

93
Q

areas storing corrosive material must have water outlets with hose or neutralizer mix of more than ____lbs

A

50lbs

94
Q

water shower and eye flusher must not exceed ____ pressure (psi)

A

25

95
Q

corrosive materials outside of building must be ____ feet away

A

5ft

96
Q

corrosive warning signs must be ___ inches high on contrasting background

A

3” minimum

97
Q

flammable aerosols in retail displays are limited to ____ gallons unless protected by automatic sprinkler and can be double that amount

A

30 gallons

98
Q

small arms ammuntion storage is based on how many lbs

A

500 lbs

99
Q

excess of 5,000lbs of small arms ammunition shall have what type of construction

A

1 hour fire resistive construction

100
Q

combustible limits stored inside have a maximum of ____ gallons in approved containers

A

60 gallons

101
Q

Class II and III liquids have a flashpoint of above or below 100f

A

over 100f

102
Q

no open flame within ______ of any auto fueling dispenser

A

25ft

103
Q

fuel dispenser hoses are a maximum of _____ ft

A

14ft

104
Q

flammable liquid containers have max of. _____ gallons

A

5 gallons

105
Q

every auto filling station requires how many extinguishers within 75ft

A

TWO 2A, 20-BC Extinguishers

106
Q

GAS PUMP SHUTOFF letters are how big

A

1”

107
Q

basements greater than _____ ft below grade are required to be sprinklered

A

4ft

108
Q

sleeping rooms in basement are required to have 1 window or ____ for escape or rescue

A

exit

109
Q

hazardous vegetation within 200ft of building or 10ft of road must not be higher than ___ inches above ground

A

3 inches

110
Q

trees and shrubs must be removed if within ____ ft of chimney outlet

A

10ft

111
Q

ponet doors must have smoke detector on each side within ___ inches of ceiling

A

12 inches

112
Q

in pre 43 retrofits, sprinkler heads inside rooms must be located where

A

above doors

113
Q

max limit of christmas trees inside building before needing permit

A

25 trees

114
Q

whats rhe minimum clearance between lightbulbs and combustible materials

A

18”

115
Q

can penthouse doors be locked

A

no

116
Q

minimum clearance in aisles towards exits

A

44inches

117
Q

panic hardware is located between 30 and ____ inches above floor

A

44”

118
Q

maximum effort to open fire rated panic hardware doors is ____ lbs

A

15lbs

119
Q

interior panic hardware should not exceed ____ lbs and exterior panic hardware should exceed _____ lbs

A

5lbs interior
8.5lbs exterior

120
Q

fire escape windows must be a minimum of ____ inches when open

A

29”

121
Q

awnings under fire escapes must have ___x____ inch opening

A

24x24”

122
Q

extinguishers less than 40lbs have max mounting height of ____ft above floor

A

5ft

123
Q

extinguishers more than 40lbs have max mounting height of ____ft above floor

A

3.5ft

124
Q

what are Class A extinguishers used for

A

Ordinary Combustibles
-wood, cloth, paper, rubber, plastics

125
Q

what are Class B extinguishers used for

A

combustible liquids
-oils, greases, tars, oil base paints, flammable gases

126
Q

what are Class C extinguishers used for

A

Energized electrical equipment

127
Q

what are Class D extinguishers used for

A

Combustible metals
-magnesium, titanium, zirconium, sodium, lithium, potassium

128
Q

Class A extinguisher requirement and distance

A

2A
-75ft

129
Q

Class B extinguisher requirement and distance

A

2A and 20B
-50ft

130
Q

Class C extinguisher requirement and distance

A

10B
-30ft

131
Q

kitchens, operating rooms, xray labs, electrical rooms require what extinguisher within immediate area

A

10BC

132
Q

a standard 2 1/2 ABC extinguisher has a rating of ____ and doe not meet LAFD requirement

A

1A-10BC

133
Q

can a water hose be used in place of extinguisher in garden?

A

yes

134
Q

garden type occupancies are not required to have portable fire extinguishers if they are

A

-apartments 15 units or less/ not more than 2 stories

  • hotels less than 19 units/ less than 2 stories
135
Q

can you have Dry Chem extinguishers in kitchens

A

no

136
Q

vehicle extinguishers are hydrostatically tested every

A

5 years

137
Q

dry chem systems are tested ___ annually

A

semi- annually

138
Q

foam, water spray, C02, halon fixed systems are tested

A

annually

139
Q

fire alarms are required in what apartment and hotel occupancies

A

-apartments 16 or more units/ 3 or more stories

-hotels with 20 or more rooms/ 3 or more stories

140
Q

fire alarm systems in hotels and apartments are checked how often by responsible person and tested _____ by Chiefs Regulation #4

A

once a month
-annually

141
Q

if a fire alarm system cannot be completely restored, what shall be stablished

A

Fire Watch

142
Q

smoke detectors are required in all sleeping room or ______ giving access to room

A

corridor

143
Q

existing single families are required to have ______ at time of sale

A

smoke detectors

144
Q

Hotels, apartments and Condominiums are required to have smoke detectors tested every ____ months

A

6

145
Q

smoke detectors must not be closer than ____ inches to ceiling

A

6 inches

146
Q

F-340D are issued to malfunctions of

A

fire doors

147
Q

are safe and sane fireworks legal in LA

A

no

148
Q

aisles as means of egress shall be no less than ____ ft wide

A

4ft

149
Q

maintain one 20B extinguisher within ___ft of drum storage

A

50ft

150
Q

top of hay piles must have ____ft clearance from sprinklers, beams, girders

A

3ft

151
Q

what are the 4 categories of 704 placards

A

left (blue): Health
top (red): Fire hazard
right (yellow): reactivity
bottom (white): specific hazard

152
Q

whats the minimum size of 704 placards

A

10”

153
Q

what hazardous materials require 704 placards

A

-flammable liquids
-corrosive materials
-oxidizing materials
-toxic materials

154
Q

hazardous refuse must maintain a minimum of ____ ft away in an approved storage bin

A

10’

155
Q

heating appliances must have a shut off valve within ___ft of appliance

A

3 ft

156
Q

lumber piles shall not be higher then ___ ft

A

20ft

157
Q

lumber piles shall not exceed ____ sqft

A

7500sqft

158
Q

lumber shall not be stored within _____ft from. a building or _____ft from opening of building

A

10ft, 15ft

159
Q

exit sign letters must be ___ inches high

A

6”

160
Q

sales areas shall not exceed ____ gallons per square feet of flammable liquids in 5 gallon containers or less

A

2 gallons per square foot

161
Q

what objects cannot be on roofs to obstruct Fire Department access or egress on roof walls or parapets

A

barbed wire, razor ribbon, fence, cable, aerial, antenna

162
Q

wires and objects or roofs of 30degrees and less must be ____ away from roof line

A

7 ft

163
Q

class 1 standpipes are located on every floor accept

A

first floor

164
Q

buildings under construction must have one standpipe when ___ stories or more and must have them installed before 50ft in height

A

6 stories

165
Q

temporary standpipes are designed to give ____gpm at 50psi with a standpipe no less than 4 inches

A

500gpm

166
Q

chutes will have sprinkler systems at top. When they exceed ____ floors, they will have additional sprinkler heads on alternate floors

A

3 or more floors

167
Q

when night club rooms exceed _____ sqft they will have sprinkler systems

A

5000

168
Q

sprinkler systems over _____ sprinkler heads will be monitored on site or offsite

A

100

169
Q

sprinkler systems are required to have a waterflow alarm when they have more than _____ sprinkler heads

A

20 sprinkler heads

170
Q

when OSY stem is all the way out, this indicates it is open or closed

A

open

171
Q

sprinkler heads need to be replaced when they are how old

A

50 years

172
Q

baffles are required on sprinkler heads to prevent them from wetting adjacent heads when they are how close together

A

within 5 ft

173
Q

storage must be _____ inches away from a sprinkler head

A

18”

174
Q

street address signs must be minimum___x____ inches

A

4” high by 2” wide

175
Q

how often do standpipes how to be tested

A

5 years