Biomaterials 3 Flashcards
Which of the following biomedical implant materials will display the highest degree of viscoelastic behavior?
a. CoCrNiMo
b. Hydroxyapatite
c. None of the choices presented
d. 316L SS
e. Zr-Mg-O-YiO2
f. Pyrolytic Carbon
None
- Which of the following is NOT associated with bone cement?
a. Shock absorption
b. Load distribution
c. Viscoelasticity
d. Osteointegration
e. All of the choices
All of the above
- Methods of creating a viable interface between skin and percutaneous implants include all except:
a. Use of felts
b. Allowing implant to “float”
c. Avoid connected leads when possible
d. Use of porous materials
e. Use of velors
f. Suture the PD and the skin for firm fixation
Suture the PD and the skin for firm fixation
- When engineering any percutaneous device, end us factors include all except:
a. Materials Selection
b. Load
c. Information transmission
d. Energy requirements
e. All of the choices
a. Materials Selection
- When performing a total hip arthroplasty, fixation may be achieved with or without the use of bone cement?
a. True
b. False
True
- Stress that are associated with cylindrical percutaneous devices include all except:
a. Torsional stress
b. Radial stress
c. Hoop Stress
d. Bending stress
e. All of the choices
c. Hoop Stress
- Which of the following is least likely to occur when bone heals under load?
a. Osteoclastic response
b. Increased bone strength
c. None of the choices presented
d. Piezoelectric response
e. All the choices are correct
f. Osteogenic response
a. Osteoclastic response
- Methodologies that you would recommend in order to investigate the threat of loosening of hand tissue implants such as knee and hip implants exclude all except?
a. Electrical Stimulation
b. Use of porous implant
c. PMMA bone cement
d. All choices are correct
e. Rigorous patient compliance
f. Ceramic coating
a. Electrical Stimulation
- Non-self tapping screws are favored due to their superior holding strength?
a. True
b. False
False
- Higher cutting forces are required for screws that have a positive rake angle.
a. False
b. True
True
- Firmness of fixation of screws when used in conjunction with a plate has a positive effect on healing.
a. True
b. False
True
- Three screw designs of different sizes are tested and evaluated for the pullout strength. Buttress, Malleolar, and Cortex it is reasonable to expect differences in their pullout strength.
a. True
b. False
True
- Natural sutures are less likely to elicit an immune response than their synthetic counterparts.
a. True
b. False
False
- Properties of ideal stent design include all except?
a. None of the Choices
b. Retrievability
c. High hoop strength
d. Thromboresistance
e. High expansion ratio
None
Which of the following is most accurate regarding heart valves?
a. Bi-leaflet valves experience less backflow than tilting disk
b. Caged disks have superior hemodynamics
c. Synthetic tissue valves have an excellent fatigue life
d. None of the choices presented are correct
e. Tissue valves are treated chemically to improve hither mechanical response
a. Bi-leaflet valves experience less backflow than tilting disk