Bentz Study Guide Flashcards

1
Q

What does VOID R stand for ?

A
V- violation of law
O- operating efficiency decreased to dangerous level
I- injury to personnel 
D- damage to equipment or apparatus 
R- response time :60 secs
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the Basic Fire Prevention Principals ?

A

Limitation
Isolation
Separation
Elimination

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the purpose of the station fire prevention program ?

A

Obtain complete coverage of the city

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What % of fire prevention should be completed every month ?

A

10%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Small arms ammo is defined as

A

.75 caliber or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many lbs of small arms ammo requires approval of Fire Prevention Bureau as to location , fire protection , warning and placards ?

A

> 1,000 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Small arms in excess of ___ lbs shall be stored in a room of 1- hour fire resistive construction

A

5,000 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Drums containing corrosive materials shall not be stacked more than ___containers high or > _____ ft high

A

2 containers high

10 feet tall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The storage of CORROSIVE materials outside of buildings shall be at least ____ ft away from building .

A

5 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Flammable aerosols may be displayed in retail sales areas ONLY if they are limited to _____gallons

A

30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Flammable aerosols > _____ gallons shall be stored in a room separate from retail sales

A

60 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

All EXISTING building that are ____ stories or more which contain group R-1 occupancies shall have sprinkler systems .

A

3 or more stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When any fire protection construction doesn’t meet the min requirements , and needs to be restored or conformed, who do you notify?

A

Building and safety with an F-338

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Sprinklers in compliance with DOROTHY MAE may use plastic pipe for what?

A

Laterals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Are the storage of flammable liquids allowed in basements ?

A

NO! Strictly prohibited

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When is a sleeping room allowed in a basement ?

A

Every room must have :
1 operable window or
Exterior door for escape

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Dispenser hoses for motor fuel in auto fueling stations are not to exceed

A

14 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Repair work involving open flame shall be kept at least _____feet from storage or garages

A

25 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Heaters in auto fueling stations must be at least _____ft from the nozzle

A

10 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

All haz vegetation or native brush within ____ ft of any structure or ____ft from the road must be no > ____in tall

A

10 feet
200 feet
3 in

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is the purpose of cutting the brush down to 3”?

A

Leave the root undisturbed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

All trees, shrubs and bushes shall be removed within ____ ft of CHIMNEYS

A

10 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Who does the company commander contact to get a no smoking replacement sign ?

A

DOT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

All curtains in assemblage areas must be fire retardant and considered good for how many years ?

A

5 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
How many gallons is a dip tank required to have a permit ?
150 gallons or more
26
A lightbulb should have a clearance of how many inches from combustible materials ?
18 inches
27
Every fuel dispenser must have a fire extinguisher with a ____rating within ____ft of each one .
2A 20BC | 75 feet
28
What form is attached when a piece of equipment or device is condemned ?
An F-336
29
What is a F-211?
Citation
30
Any complaint of a hazard received at the fire station should be inspected no later than….
No later than the next day
31
How should fire prevention notices be served?
Personally or US mail
32
If a building is closed and an F-340 is mailed for a needed inspection , how long does the owner have to respond ?
30 days
33
What is the inspection cycle at the fire station (general) based on?
Number of exits
34
When are assembly occupancies <100 inspected ?
2 times a year Once during day once during night 6 months apart
35
Fire prevention BUREAU occupancies shall be inspected when and for what?
Every 3 years for pre fire planning
36
How often is a 3 story garden style apt inspected ?
Once a year
37
Enclosed corridor hotels that are <3 stories and 6-19 guest rooms are inspected how often ?
Every 3 years
38
Enclosed corridor apt’s <3 stories and are 5-15 units are inspected how often ?
Every 3 years
39
When can a 1 1/2” garden hose be used in lieu of a fire extinguisher ?
The hose has to be 50 feet or less
40
How far are extinguishers apart from eachother in hotels and apartments ?
75 feet
41
Minimum size for EXIT signs
No <6 “ tall
42
Extinguishers on vehicles shall be hydrostatically tested every ____years
5 years
43
Local fire alarm required when apartment is ______ | Hotel is _____
Apt 3 or > stories 16 or > units | Hotel 3 or > stories 20 or > guest rooms
44
Aisles where COMBUSTIBLE LIQUIDS are stored shall be no less than
4 feet wide
45
What is the max amount of FLAM OR COMB LIQUID stored in one cabinet?
60 gallons
46
What is the minimum dimension for a fire escape window ?
29”
47
Minimum size for NFPA Placard
10 inches
48
How many building inventory sheets are required in a lock box ?
4
49
Under which index in the Building Inventory Program would an occupancy on 37th st be filed ?
7 | *anything over 10, use the last digit
50
What is the Building Inventory Program designed for ?
Basic info on specific buildings
51
Buildings in the Building Inventory Program get their 7 digit location number from where ?
800’ hydrant map book
52
How far off the ground should the stairwell numbering sign be ?
5 ft
53
What keys are required in FF lock boxes ?
Stairwell keys | Elevator keys with instructions
54
Multi unit dwellings that are <3 stories are inspected when
Every 3 years
55
The bottom of the stairwell numbering sign shall be located not less than how many feet above the floor ?
5 feet
56
Inspections to certify hazmat inventories on BP8’s are conducted how often
Every 3 years
57
Aircraft inventory program :how often should firefighting inspections normally be made of each type of aircraft?
At least once a year by each platoon
58
Aircraft inventory program : when is an aircraft inventory sheet required on an aircraft ?
Over 12,500 lbs in weight and used daily
59
Aircraft inventory program : What do the 3 colors mean for the plan sheet on an aircraft ?
``` Red= exits Yellow = oxygen Blue = fuel ```
60
Aircraft inventory program : aircraft inventories shall be filed by:
Manufacturer: alphabetically
61
Brush inventory program : an adequate time for companies to complete brush inventories is :
60 days
62
Brush inventory program : the 3rd line on the sheet gives a 7 digit # showing the main access of the area , where is this obtained ?
The 1200’ map book
63
Brush inventory program : when should station commanders review their districts ?
May- July
64
A local Waterloo alarm system shall be provided on all sprinkler systems with ____ heads or more
20 heads
65
A sprinkler system needs to be supervised by an approved remote station w/ an audible signal constantly when _____heads or more
100
66
Materials treated with fire retardant are good for how many years?
5 years
67
All complaints requiring legal action due to the sale or storage of fireworks within the city should be referred to whom?
The Legal Liaison Unit
68
Buildings or structures that are to be closed to entry shall be posted w an ____ to prohibit entry
F-339
69
No cylinder or tank of liquified flammable gas shall be filled within ____feet if any building .
25 feet
70
Lumber shall not be stored within ___ft of any building or within ___ft of any unprotected opening of a building .
10 feet | 15 feet
71
How many feet of access shall be maintained around standpipe valves ?
3 feet
72
At what age should sprinkler heads be replaced ?
50 years old
73
What form must a building owner obtain before entering a premises that is posted with an F-339?
An F -315
74
Piles of lumber shall not exceed _____square feet of ground area
7500 sq feet
75
Pallet piles shall be stored no more than ____feet high .
6 feet
76
What is the minimum size for an address number?
4” high 2” wide