BE400 Electrical Flashcards

0
Q

What are the power sources for the DC electrical system?

A

Battery, external power, generators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

When is a GPU start recommended?

A

Ambient temperatures below -15C.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the 3 separate parts of the electrical system?

A

28V DC, 115/26V AC, Standby power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What makes up the 28V DC system?

A

1 main battery, 1 standby battery, 2 engine generators, external power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What bus is used for battery charging?

A

Battery charge bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What powers the emergency bus?

A

The L load bus or the emergency battery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where is the standby battery located?

A

The nose electronic compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What type of battery is the emergency battery?

A

24 volt 5 amp/hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What’s the amperage of the 28V GPU?

A

1000-1500 amps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What cools the DC generators?

A

Ram air in flight and fans on the ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Are batteries used during cross-generator starts?

A

Yes. To achieve a faster, cooler start

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When is the GEN relay opened automatically?

A

GCU detects a malfunction or Fire switch light has been pushed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What protection does the GCU incorporate?

A

Reverse current, differential fault, over voltage(32 volts), ground faults

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When is the Gen Relay light expected to be on?

A

When respective Gen switch is off, when a fire switch light had been pushed, N2 less than 35-45% and/or start select on L/R, or Gen failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does L/R GEN OFF light mean?

A

GEN relay is open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When will a generator trip?

A
  • overvoltage
  • feeder faults
  • engine fire switch
16
Q

What is the purpose of the load bus tie relay?

A

Connects left and right load buses to run off one power source

17
Q

What is the purpose of the load bus tie over-current relay?

A

To protect l/r secondary distribution system in case of a short

18
Q

Load bus tie relay opens if over-current exceeds…

A

100 amps

19
Q

Can you reset bus tie over current manually?

A

Yes

20
Q

What is required to close the Utility Bus relay (RCCB)?

A

EXT PWR on or both generators on

21
Q

Where does battery normally receive power?

A

BATT Charge Bus

22
Q

The battery is also connected to which bus?

A

Start bus

23
Q

With GEN MASTER switches in EMER, what will placing the battery switch in EMER do?

A

Connect battery bus to EMER BUS

24
Q

What do feeder cables do?

A

Provide connection between power sources and load buses

25
Q

Which components are powered by Standby Power?

A
  • Standby Att. Indicator
  • Standby Alt. Vibrator
  • Backlighting for stby: att ind., alt., airspeed ind., magnetic compass
  • STBY ARM/ON light
  • Left ITT
  • RTU 1
26
Q

What is the power source for the 115/26V AC system?

A

2 static 115/26V AC 400Hz inverters powered by DC system

27
Q

What powers the emergency lighting?

A

Two 6VDC lead-acid batteries. One under cabin floor, one behind the aft pressure bulkhead