Basic Pumping Ops Flashcards

1
Q

1.5
The Volume position is to be utilized as a standard operating procedure. ALL FDNY pumpers are to be maintained in Volume setting unless_____?

A

Upon arrival at the scene of an operation, head pressures must be overcome.
(standpipe operations)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Lowest RPM that an apparatus is capable of achieving.

A

Engine Idle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Pump Idle Pressure =

A

The pressure the pump pressure gauge will read when the apparatus is in its lowest RPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Pump Idle Pressure ALWAYS =_______+______?

A

the pressure the pumps provide at its lowest RPMs (around 55 psi in volume or around 110 psi in pressure) + water intake receives from a water source.
ex: hydrant pressure of 50 psi plus idle pressure in volume 55 psi will equal a pump idle pressure of 105psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The Pro Pressure Governor operates in two modes what are they?

A

1) Pressure Mode- in this mode the PPG will automatically maintain the discharge pressure set in the LED display

2) RPM Mode- will maintain engine RPMs set in the LED display.
However, WILL NOT automatically compensate for any changes in discharge pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

True or False
In emergencies, RPM mode is used as a backup in the event that the pressure Mode malfunctions. It can maintain adequate pressure and all handlines will operate the same regardless.

A

False.
In emergencies it is used as a backup however, if this should occur, ANY hoselines in operation should not advance and should back out to an area of safe refuge.
FDNY uses the PPG in pressure mode only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Residual pressure indicates what?

A

Ramaining capability a hydrant has to supply water INDICATED ON THE INTAKE PRESSURE GAUGE, ONCE WATER IS FLOWING.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Flowmeters measure the rate water will flow in GPMs but only when_____

A

Water is flowing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The Officer calls for more water in an 1 3/4” hand line, the ECC notes a flowmeter reading of 110 gpm. This indicates the possibility of _______?

A

Kinks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Officer reports no water at the nozzle of an 1 3/4” hand line or decrease in pressure at the nozzle and the ECC notes a flowmeter reading of 230 gpm. This indicates:

A

Possibility that there could be a burst length

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

To flush a hydrant when testing it, you must open it fully. True or False?

A

False.
DO NOT OPEN FULLY.
*let the gentle water flow push out any debris without forcing it up into the barrel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What two hydrant connections are suggested for 1st to arrive engines on the 1st alarm?

A

10’ small, OR the 35’ soft hydrant connection SHOULD be used

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When other than 1st to arrive on the 1st alarm what hydrant connections should be used?

A
10' small suction
10' hard suction
35' soft
*this says SHOULD not MUST.
*NOTICE 3 1/2" IS NOT SUGGESTED FOR ANY 1ST DUE UNITS OR 2ND ALARM UNITS.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How should second alarm or greater engine companies connect to hydrants?

A

10’ hard suction should be used

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

T or F

An Engine Company drafting can use any means available to get water.

A

FALSE

  • *MUST USE 10’ HARD SUCTION
  • *ONLY MUST
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

T or F

An Engine Company drafting can use any means available to get water.

A

FATLSE

  • *MUST USE 10’ HARD SUCTION
  • *ONLY MUST
17
Q

What should the initial supply line be for in-line pumping operations?

A

3 1/2” hose

18
Q

When residual pressure drops below____psi on the intake pressure gauge, augmentation will be required.

A

BELOW 15 psi- residual pressure

19
Q

What shall be done if the Pro Pressure Governor malfunctions?

A

The apparatus shall be placed OOS.

20
Q

What are the steps for getting a single handline into operation using hydrant water?

A

4 P’s

1) Once water is entering the apparatus, engage pumps
2) Prime the pumps
3) Depress the Preset Button
4) Determine pressure required
5) Slowly open the discharge outlet until the desired pressure is reached.
* *the PPG will adjust engine speed to maintain indicated pump pressure.

21
Q

What hydrant connections should the supply pumper use in a Water Relay?

A

10’ or 35’ connection

Evolutions 8 3.3

22
Q

Other than in standpipe ops, both the supply and operating pumpers operate in Volume position at ALL water relay operations. True or False?

A

True
Exception is a pumper being supplied in a standpipe operation still operates in PRESSURE. Supply pumper operates in VOLUME.
(Evolutions 8)