1.5
The Volume position is to be utilized as a standard operating procedure. ALL FDNY pumpers are to be maintained in Volume setting unless_____?
Upon arrival at the scene of an operation, head pressures must be overcome.
(standpipe operations)
Lowest RPM that an apparatus is capable of achieving.
Engine Idle
Pump Idle Pressure =
The pressure the pump pressure gauge will read when the apparatus is in its lowest RPM
Pump Idle Pressure ALWAYS =_______+______?
the pressure the pumps provide at its lowest RPMs (around 55 psi in volume or around 110 psi in pressure) + water intake receives from a water source.
ex: hydrant pressure of 50 psi plus idle pressure in volume 55 psi will equal a pump idle pressure of 105psi
The Pro Pressure Governor operates in two modes what are they?
1) Pressure Mode- in this mode the PPG will automatically maintain the discharge pressure set in the LED display
2) RPM Mode- will maintain engine RPMs set in the LED display.
However, WILL NOT automatically compensate for any changes in discharge pressure.
True or False
In emergencies, RPM mode is used as a backup in the event that the pressure Mode malfunctions. It can maintain adequate pressure and all handlines will operate the same regardless.
False.
In emergencies it is used as a backup however, if this should occur, ANY hoselines in operation should not advance and should back out to an area of safe refuge.
FDNY uses the PPG in pressure mode only
Residual pressure indicates what?
Ramaining capability a hydrant has to supply water INDICATED ON THE INTAKE PRESSURE GAUGE, ONCE WATER IS FLOWING.
Flowmeters measure the rate water will flow in GPMs but only when_____
Water is flowing
The Officer calls for more water in an 1 3/4” hand line, the ECC notes a flowmeter reading of 110 gpm. This indicates the possibility of _______?
Kinks
Officer reports no water at the nozzle of an 1 3/4” hand line or decrease in pressure at the nozzle and the ECC notes a flowmeter reading of 230 gpm. This indicates:
Possibility that there could be a burst length
To flush a hydrant when testing it, you must open it fully. True or False?
False.
DO NOT OPEN FULLY.
*let the gentle water flow push out any debris without forcing it up into the barrel.
What two hydrant connections are suggested for 1st to arrive engines on the 1st alarm?
10’ small, OR the 35’ soft hydrant connection SHOULD be used
When other than 1st to arrive on the 1st alarm what hydrant connections should be used?
10' small suction 10' hard suction 35' soft *this says SHOULD not MUST. *NOTICE 3 1/2" IS NOT SUGGESTED FOR ANY 1ST DUE UNITS OR 2ND ALARM UNITS.
How should second alarm or greater engine companies connect to hydrants?
10’ hard suction should be used
T or F
An Engine Company drafting can use any means available to get water.
FALSE
- *MUST USE 10’ HARD SUCTION
- *ONLY MUST