Basement firefighting Flashcards
Best place for IC
surface level unless pre planning show better location
Decision to ventilate must take into account?
adverse effect on persons involved
benefits for firefighters entering or persons evacuating
who could be requested for advice prior to ventilation
SFSO
Basement procedure implementation requires
BA teams to the basement with minimum 45 mm jet set to 230 lpm
BA team with minimum 45 mm jet set to 230 lpm protecting egress route
Good considerations for basement firefighting
weight of attack (45 mm 230 lpm) access and egress routes clear and protected (45 mm 230 lpm) stage II BA EDBA guidelines (complex layouts) leaky feeder
prior to ventilation what must be put in place
BA teams withdrawn
covering jets at all outlets
incorrect ventilation may
adversely affect those involved
result in rapid and uncontrolled fire spread
lead to back draught conditions
fixed installations may include
AFA mechanical ventilation or smoke extraction falling mains sprinklers foam inlets gas flooding systems protected shafts and lifts