What is the working duration on a SDBA?
31 minutes at 50 litres per minute
What does STOPCAB mean in relation to BA?
Self Contained Two stage Open circuit Positive pressure Compressed Air Breathing apparatus set
What are the two functions of the inner mask?
To prevent misting
And
To prevent the build up of carbon dioxide
How long, after no movement, will the bodyguard 7000 go into pre alarm?
30 seconds
How long will the bodyguard 7000 sound a pre alarm before full ADSU alarm?
15 seconds
At what pressure will the electronic low pressure warning device operate?
How long does this give you at 50 litres a minute?
84 bar
12 minutes
At what pressure will the pneumatic low pressure warning whistle operate?
74 + or - 5 bar
What colour are the rally’s for SDBA and EDBA?
Yellow and red
How many times on a single SDBA set is it’s ID number displayed and where are they?
Mask Lung demand valve Back plate- inside Back plate- outside Telemetry module Tally On the bodyguard 7000