B744 ECS PANEL Flashcards
What happens to the Outflow Valves upon Touchdown?
They go full open
If one Outflow Valve is in MAN, will the other Outflow Valve operate in AUTO?
YES
Where/When can I observe Cabin Alt & Rate, Landing Alt?
Primary EICAS Display when: - Landing Alt in Manual - Cabin Alt in Caution or Warning - Cabin Differential Press in Caution or Warning ECS or ENG selected on Secondary EICAS
Is there auto switching of Cabin Altitude controllers if one should fail?
YES
When does the Cabin ALT warning siren sound?
Cabin Altitude excessive (>10,000’)
What is the max allowable cabin differential pressure for T/O & Landing?
.11 psi
What is the max differential pressure (relief valves)?
9.4 psi
How many positive pressure relief valves are there and where are they located?
2
E and E compartment, left front compartment
Where are the negative pressure relief valves located?
Cargo doors (side, fwd & aft)
What is the Temp° range for the Flt Deck?
18°-29°C (65°-85°F)
What does the Manual position of the Temp° controllers do?
Sets the Trim air valves manually
What will cause a Zone Sys Fault light to illuminate?
Ø Temp° Zone duct overheat Ø Zone Temp° Controller fault Ø Master Trim air valve closed Ø Trim air switch OFF Ø Master Trim air valve closed and pack air still flowing
What will cause a Pack Sys Fault light to illuminate?
- Pack Overheat or other Sys fault
- May illuminate briefly while switching between controller (Auto or Manual)
What happens when I press the Trim Air switch to OFF?
Ø Master Trim Air valve closes
Ø Pack output temp° in backup mode (18°-29°C) as selected by Flt Deck selector in AUTO
Ø No control of Flt Deck, Upper Deck or main Deck
Ø Pack controller A only
On the ground, engines not running, where is Equip Cooling exhaust air routed?
Into the Lower Fwd Cargo compartment when temp° < 7°C
Overboard when temp° > 7°C