B717 FWD Doors Arming
“Top to Bottom”
Place red warning flag across the viewing window
Remove girt bar from stowage bracket and insert into floor fitting
B717 FWD Doors Disarming
“Bottom to Top” Remove girt bar from floor fitting and secure into stowage bracket Remove red warning flag from viewing window
B717 FWD Doors Opening Normal Mode
Assess
Rotate door control handel towards the nose of the A/C
Push door out until it latches onto the fuselage
B717 FWD Doors Closing
Squeeze door latach release handle and pull door closed using door assist handle
Rotate door control handle AFT to the locked position
B717 FWD Doors Emergency Opening
Assess
Rotate door control handle toward the nose of the A/C
Push door out until it latches onto the fuselage
Pull red manual inflation handle
B717 Tailcone Exit Arming
Disengage the secondary lock
Lower the center headrest pad, exposing the emergency door control handle and red plastic guard cover
B717 Tailcone Disarming
Raise center headrest pad
Engage secondary lock, exposing the normal door control handle
B717 “Circle Check”
Physically check lavatory is unoccupied
Put up red barrier strap across the aisle
Check galley area is secure
Check AFT exit door is armed
Strap yourself into AFT J/S
B717 Tailcone Emergency Opening
Assess over the red barrier strap, then though peep hole
Remove red plastic guard cover
Rotate emergency door control handle A/C L
Pull door inward until engaged on lavatory latch
Assess down catwalk to ensure tailcone has jettisoned & slide has inflated (inflation indicators, green and white stripes)
Proceed down catwalk and assume protect position
B717 Tailcone BackUp Procedures for when Tailcone fails to jettison slide doesn’t deploy
If tailcone fails to jettison: Pull tailcone jettison handle located on A/C L
If that fails; assume protect position and stop twice with one foot on the tailcone separation
If tailbone drops, but slide doesn’t deploy: Lift red handle up and away
Pull red manual inflation handle
If all backups fail, block the exit and redirect PAX to a useable exit
B717 Tailcone Blocking Procedure
Release door from the lavatory latch
Rotate emergency door control handle A/C R to lower arming rod
Replace red plastic guard cover
Disarm the AFT Exit Door
Close door by rotating normal door control handle A/C R
Replace red barrier strap & block exit
Proceed to OVWG exit
B717 OVWG Exits Procedure
Assess
Facing AFT
Open window using asile hand to pull on the Window Release Handle inboard
Turn
Throw window out
B717 Cockpit Clear-view Window and Escape Ropes
Pull black ball AFT - Inboard - AFT
Escape Ropes Open Compartment: Throw the the escape rope out of window - look for color change to know when fully extended
Wrap the rope around your hand
Lower yourself to the ground