1
Q
What is the Maximum permissible load on the APU Generator?
A
40 KVA
2
Q
What is the Maximum altitude for starting the APU?
A
37,000 Ft
3
Q
What is the Maximum altitude for APU Operations?
A
41,000 Ft
4
Q
Maximum Speed with APU Door Open (Not Operating)
A
220 Kts
5
Q
Minimum Battery Voltage for APU start
A
22 V (Both Batteries)
6
Q
What function does the MAIN BATTERY serve during an APU start?
A
Powers the APU ECU
7
Q
What function does the APU BATTERY serve during an APU start?
A
Powers the APU Starter
8
Q
When will the AVAIL switch-light illuminate?
A
2 Seconds after the RPM has reached 99% (99% +2Sec)