Describe control room ventilation flow path.

A

From outside through missile barrier, dampers, roughing filter, HEPA filter, fan, heating coil, backdraft damper, humidifier.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the purpose of control room ventilation?

A

To maintain:

  • Temperature within required limits. (normally 75F and 30-50% humidity)(90-95F under most adverse conditions)
  • Acceptable smoke level.
  • Positive Pressure following a LOCA.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the control room pressurization fan flow path?

A

Outside through snow plenum, through dampers 2 or 2A, through roughing filter, HEPA filter, Charcoal filter, through fans, backdraft damper.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Auto starts of control room pressurization system?

A

All 4 fans start on SI.

Hi Rad signal, and fire in that unit will start the fan in that unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What will close Damper 3A in the control room pressurization system?

A

Fire in cable vault.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What does the CRAC Humidifiers use to maintain humidity?

A

DI water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the back up cooling water supply for the CRAC?

A

ESW.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Why do we maintain a bubble in the expansion tank on the CRAC chill water system?

A

With an air bubble established A small loss of water will have no functional effect on system pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

In what modes must the control room emergency ventilation systems be operable?

A

Modes 1-4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When the TSC ventilation system is in emergency mode what is realigned?

A

All air is aligned to go through the charcoal filters.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the purpose of auxiliary building ventilation?

A

To maintain a negative pressure in the auxiliary building to minimize the possibility of unmonitored radioactive gas release.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How do the CCW fans cool the CCW pumps?

A

Blow air on them

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where are the CCW fans located?

A

U2.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is required to cool CCW pumps?

A

2 Unit 2 AS fans, or 1 U2 AS fan and 1 CCW fan, or 2CCW fans.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What must you start before you start an AS fan?

A

AX fan.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the AES flow path?

A

Takes a suction from hallways into ESF pump and HX rooms, into the vestibule, through roughing filter then HEPA filter then through or around charcoal filter, through fan then out plant vent stack. CLEAN TO DIRTY

17
Q

What are the auto starts of the AES fans?

A

If switch is in AUTO will start when same train ESF pump starts. SI starts all AES fans.

18
Q

What happens to the AES fans if either train of Phase B signal occurs?

A

Both AES fans will go into charcoal filter mode.

19
Q

Who must you contact when changing any Aux building ventilation?

A

RP