ATA 80 - Engine Starting Flashcards
What is the engines self sustaining speed?
55% Ng
When will the GCU disconnect the starter generator?
When Ng has reached 55%. (self sustaining speed)
What is the maximum ITT for starting the engine?
175° celcius
How is the starter generator powered?
From the PDU (Power Distribution Unit)
Is there a temperature limit for battery start?
Yes, it must not be below -20°c
Which duty cycle is applicable when starting with external power?
2 start attempts with three minutes cooling in between. Thereafter 25 minutes must elapse until a third attempt.
Which duty cycle is applicable when starting with aircraft batteries?
2 start attempts with five minutes cooling in between. Thereafter 25 minutes must elapse until a third attempt.
Which duty cycle is applicable when motoring?
3 ea 20-seconds ventilation runs with 30 seconds cooling time elapsed between each attempt. Thereafter one hour of cooling time is needed.