ATA 80 - Engine Starting Flashcards

1
Q

What is the engines self sustaining speed?

A

55% Ng

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When will the GCU disconnect the starter generator?

A

When Ng has reached 55%. (self sustaining speed)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the maximum ITT for starting the engine?

A

175° celcius

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How is the starter generator powered?

A

From the PDU (Power Distribution Unit)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Is there a temperature limit for battery start?

A

Yes, it must not be below -20°c

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which duty cycle is applicable when starting with external power?

A

2 start attempts with three minutes cooling in between. Thereafter 25 minutes must elapse until a third attempt.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which duty cycle is applicable when starting with aircraft batteries?

A

2 start attempts with five minutes cooling in between. Thereafter 25 minutes must elapse until a third attempt.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which duty cycle is applicable when motoring?

A

3 ea 20-seconds ventilation runs with 30 seconds cooling time elapsed between each attempt. Thereafter one hour of cooling time is needed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly