ATA 49 - APU Flashcards

1
Q

Combien d’APU Start ?

A

After three consecutive APU start attempts, the flight crew must wait 60 min before a new start attempt.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Max EGT for APU running ?

A

Maximum EGT for APU running (with 5 s confirmation for shutdown) 682 °C
Maximum EGT for APU running (for immediate shutdown) 700 °C to 742 °C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

APU BLEED ?

A

2 packs : FL150
1 pack : FL200

Max altitude for engine restart with APU BLEED : FL200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Démarrage APU sur batteries ?

A

FL250

How well did you know this?
1
Not at all
2
3
4
5
Perfectly