Area 25 Exam Flashcards

1
Q

A check valve is used to prevent a __.

A

backflow of water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Positive displacement pumps _____.

A

move a fixed amount of liquid with each cycle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The most efficient method for calibrating a boom sprayer in the field is _____.

A

measure nozzle flow rates over a timed interval

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The most important factor in replacing an electric motor is _____.

A

specs of the original motor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

One acre encompasses _____.

A

43,560 square feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A milliampere is _____.

A

0.001 ampere

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The horsepower rating on an electric motor indicates _____.

A

work output capacity over time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

An item not typically found in a sprayer operator’s manual is _____.

A

recommended spare parts suppliers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The most common quick shut-off valve is a _____.

A

ball valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

On a 1/6 hp motor, reset a tripped circuit breaker by _____.

A

push the breaker all the way off & turn it on again

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If a circuit trips repeatedly _____.

A

ID & correct the cause before resetting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

To apply 3 pints/acre of pesticide in 11 gallons of spray solution, to a 300-gallon tank, add _____.

A

10.22 gallons of pesticide

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Pipe fittings are sized to the specific _____.

A

pipe size

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

NEMA is the acronym for _____.

A

National Electrical Manufacturer’s Association

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The appropriate electric conductor classification for installations subject to heat & moisture is _____.

A

THWN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

A sesame field of 827,326 square feet contains _____.

A

19 acres

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Common types of strainers do not include _____.

A

sump strainers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

When wiring an electric motor to a 3-conductor, 120v circuit according to NEC, attach the green motor
lead to the _____.

A

bare wire on the cable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

PVC pipe is most often joined with _____.

A

slip fittings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

PVC fittings are not designed to _____.

A

strengthen pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

To pull conductors through conduit, use a _____.

A

fish tape

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

At the end of each spraying season, tips and screens should be _____.

A

removed, cleaned, and stored in diesel fuel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Rate of electric current flow in electric motors is measured in _____.

A

amperes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

PVC pipe is generally sold in _____.

A

10’ & 20’ lengths

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
The ASABE hand signal to raise a spray boom is _____.
point your arm & fingers downward and make a circular motion
26
Boom sprayer pumps are rated by _____.
flow in GPM / LPM at specified speed & pressure
27
When connecting magnetic motor starters _____.
wire the start switch in parallel
28
To change direction of shaft rotation on an electric motor, you need to _____.
reverse the starting & running windings
29
The function of the pressure regulator in a boom sprayer is to _____.
maintain consistent system pressure to ensure the proper application rate
30
To control a 3-phase pump motor, use a _____.
three-pole switch
31
Residential wastewater is also called _____.
effluent
32
The two types of pumps used on boom sprayers are positive displacement pumps and _____.
centrifugal pumps
33
During heavy use seasons, clean your boom sprayer nozzles & filters _____.
after every chemical change
34
You will find safety words such as duck, watch out, and danger positioned near _____.
hazards
35
A pressure switch in a pump system is activated by _____.
water system pressure
36
PVC pipe is generally available in _____.
Sch 40 & 80
37
A critical task in ensuring a leak-free PVC joint after gluing is _____.
making a 1/4 turn after inserting the pipe fully into the fitting
38
A cable to an electric motor consisting of #10 conductors, with one red, one white, one black and one ground will be stamped _____.
10/3 WG
39
On a 240-v circuit, an effective control device would be a _____.
double-pole motor controller
40
To clean PVC pipe mechanically, you can use a _____.
pocket knife
41
A motor with a high service factor can _____.
be overloaded for short periods without damage
42
PVC pipe is used in septic systems for _____.
subsurface field drainage
43
To ensure accurate application with a boom sprayer _____.
adjust the nozzle pressure & flow rate to match your target application rate
44
To size a 3" PVC pipe to a 2" pipe, use a _____
reducer
45
Before operating a boom sprayer in a new field _____.
calibrate the sprayer based on field conditions and application needs
46
Information not typically found on an electric motor nameplate is _____.
wire color code
47
Burrs on PVC pipe may also be cleaned with _____.
sandpaper
48
VRA technology components do not include _____.
rotators
49
PVC pipe is not well-suited for _____
warm water
50
Agitate the liquid in the spray tank by _____.
bubbling air into the tank
51
The motor control device for a 2 hp or greater motor should be _____.
in hp, not greater than the hp of the motor
52
Pumps on boom sprayers are generally designed to operate at pressures of _____.
20-40 psi
53
To double the flow rate, increase the pressure _____.
by a factor of 4
54
A boom sprayer that covers 500' in 48 seconds travels at _____.
7.1 mph
55
Rotary pumps _____.
use gears and vanes to move fluid
56
Exposed residential wiring is referred to as _____.
surface wiring
57
When adjusting nozzle settings in the field, do not drive your boom sprayer _____.
36' for a 60' spacing
58
PVC pipe can be marked prior to cutting with a _____.
marker
59
Use a GFCI with a portable electric pump to _____.
break the circuit if a difference in current exists between the hot and bare conductors
60
Properly-sized branch circuit conductors that supply electric motors should carry _____.
125% of the motor's full-load amperage rating
61
PVC pipe connections should be cleaned both mechanically and _____.
chemically
62
33,000 ft.-lbs./minute equals _____.
1 hp
63
Place switches and controls on _____.
hot wires connecting the load to the source
64
Under prolonged exposure to sunlight, PVC pipe tends to _____.
lose its strength
65
To apply herbicides with minimal drift, use a _____.
flat fan nozzle with air induction
66
PVC pipe connections are made with _____.
solvent
67
The purpose of the boom sprayer's agitation system is to _____.
maintain the chemical mix uniformly in the solution
68
Residential waste systems irrigate open land by incorporating _____.
surface application systems
69
Motor controllers must have an Hp rating that is _____.
1.25 X the rating of the motor
70
A motor control system's thermal overload protector prevents _____.
overheating due to excessive current
71
Loose electrical connections will cause _____.
high resistance
72
Using a 2 hp motor to pump 40,000 gallons of water into a chemigation system at the rate of 150 gallons/hour with a power cost of $0.03/KWH will cost about _____.
16.02
73
Electric energy usage by motors is measured in _____.
watts
74
The longest-wearing boom sprayer nozzle tips are manufactured from _____.
ceramic materials
75
Electrical supplies such as conductors, switches, and receptacles should be approved by _____.
UL
76
To compensate for wear, sprayer pumps should have a reserve capacity of _____.
10-20%
77
The color of conductor used to ground 120V circuits is _____.
green
78
The highest tensile strength for a steel bolt is SAE GRADE _____.
8
79
Positive displacement pumps do not include _____.
centrifugal pumps
80
To shut off water flow in an irrigation system, use a _____.
globe valve
81
Motor controllers & sensing devices must meet specifications outlined in the _____.
NEC
82
PVC primer is generally colored _____.
purple
83
In a correctly-wired circuit serving a 120v electrical motor, according to NEC, the neutral wire _____.
is a current-carrying conductor
84
A magnetic relay is most often used to _____.
start a motor circuit remotely
85
Minimize chemical spray drift by _____.
lowering boom height and selecting proper nozzles
86
Flow rates can increase due to _____.
nozzle tip wear
87
A 120v, 5 hp electric motor has a theoretical wattage consumption of _____.
5000 watts
88
Use a tachometer to measure _____.
RPM
89
Sprayer nozzle screens should be _____.
slightly smaller than the nozzle tip
90
To prevent power surges in an electrical system, install a _____.
circuit breaker
91
To clean PVC pipe chemically, use special _____.
primer
92
A PTO rated at 1000 rpm has _____.
21 splines
93
a 7.5' diameter wheel turning with a force of 675 lbs. develops _____.
5062 foot-pounds of torque
94
A motor that runs a transfer pump to fill a boom sprayer should be protected by a _____.
GFCI
95
A half-section of land contains _____.
320 acres
96
A clogged nozzle in a boom sprayer often results in _____.
uneven chemical distribution across the spray width
97
A control device that responds to the presence or absence of light is a _____.
photoelectric sensor
98
Variable Rate Application (VRA) technology does not use _____.
isobar maps
99
One mile per hour (MPH) equals _____.
88 fpm
100
Rural water supply systems use PVC pipe for _____.
distribution lines & residential connections