ARDS: OSCILLATE Flashcards

1
Q

Clinical Question OSCILLATE

A

In patients is moderate to severe early ARDS, does high-frequency oscillatory ventilation reduce in-hospital mortality?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

OSCILLATE Bottom Line

A

In patients with moderate to severe early ARDS, early high-frequency oscillatory ventilation might increase in-hospital mortality

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

OSCILLATE Primary outcome

A

In-hospital mortality

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is HFOV

A

high-frequency oscillatory ventilation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

OSCILLATE criticisms

A
  • The authors identify that the trial was stopped early despite the stopping thresholds not being met and that the high mean airway pressure HFOV protocol may have led to worse outcomes than one with lower pressures
  • The sedation strategy in the HFOV group may have led to higher mortality as patients may have been given higher doses of sedative and, subsequently, fluids

-The HFOV may have been initiated too late
Successful HFOV may take expertise not present at the study centers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly