Q

Starter Operation - Ground start

A

3 attempts with 1 minute rest intervals

After 3 attempts, allow 20-minutes of cooling.

2 additional attempts followed by a 40-minute cooling off period.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Starter Operation - Air Start

A

Only 1 attempt permitted

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Max altitude for start

A

FL300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Max Operating altitude

A

FL370

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Max airspeed for start

A

285 KIAS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Max altitude for assisted start for left engine

A

9,000 ft