APU Flashcards
if the apu LOW OIL LEVEL ECAM advisory is displayed….
The APU may be started.
Maintenance action is required
within next 10 h of APU operation.
APU STARTER LIMITATIONS
After 3 starter motor duty cycles,
wait 60 min before attempting
3 more cycles.
APU ROTOR SPEED LIMITATION
Maximum N
(ECAM display)…………. 107 %
APU EGT LIMITATIONS
MSN 2204-2296, 3252, 3317
Maximum EGT for start:
Below 25 000 ft……………………………… 900 °C
Above 25 000 ft……………………………… 982 °C
Maximum EGT, with APU running:
‐ 682 °C, with 5 s confirmation time for shutdown, or
‐ From 700 °C to 742 °C for immediate shutdown.
APU EGT LIMITATIONS
MSN 1140-1159, 2657-3175,
3253-3279, 3450-5212
Maximum EGT…………………………………….. 675 °C
Maximum for start (below 35 000 ft)……….. 1 090 °C
Maximum for start (above 35 000 ft)……….. 1 120 °C
In the APU start envelope, the APU start is guaranteed within …..
3 consecutive start attempts
APU Electric power
90 KVA extraction:
At or below 25 000 ft:
ISA + 35 °C and below
APU MAXIMUM ALTITUDE FOR BLEED AIR
-TWO PACKS UP TO 15 000 ft
-ONE PACK UP TO 20 000 (22 500) ft
-ENG START:
UP TO 15 000 ft IF SPEED BELOW 150 kt
UP TO 20 000 ft IF SPEED ABOVE 150 (180) kt