APU Flashcards

1
Q

Generator load limit

A

Sundstrand = 1.0

PATS = .67

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

APU start limit

A

1 = 1min on, 2min off
2 = 1min on, 2min off
3 = 1min on, 2min off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What happens if APU is left on during takeoff?

A

Auto shut down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When must the APU fire detect test be performed?

A

Prior to APU start

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Do the cockpit and cabin auto/man AC modes also control temp using APU bleed?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If the YELLOW starter and GREEN run advisory lights illuminate after APU start, what is the pilots action?

A

Remove APU power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which buses are powered by the APU?

A

All DC buses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What happens to the APU bleed valve of CABIN DUCT HOT or FLT COMP DUCT HOT caution lights illuminate?

A

APU bleed valve closes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the meaning of the yellow WRN advisory light on APU Gen switch?

A

APU off line or failed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When is APU fuel supply available for use?

A

When the APU power switch is pushed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is indicated by illumination of RBY OHT advisory light?

A

Rear bay where APU located has over heated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Three conditions that cause APU caution light illumination?

A

APU shut down by ESU due malfunction or fire

APU fire detection test conducted

APU Gen not online or failed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly