API 577 (Welding Inspection and Metallurgy) Flashcards

0
Q

API 577

A calibration block must be within what temperature of the part to be examined (UT Calibration)?

A

API 577 (9) Non-destructive Examination
(9.9) ULTRASONIC INSPECTION (UT)
(9.9.1) Ultrasonic Inspection System Calibration
25 degrees F
Calibration system checks should be performed prior to and at the completion of an examination. In addition, a system check is required with any change in the search unit, cabling, and examiner. The temperature of the calibration standard should be within 25°F (14°C) of the part to be exam- ined. If the temperature falls out of that range, the reference standard is brought to within 25°F (14°C), and a calibration check should be performed. For high temperature work, special high temperature transducers and couplants are usually necessary. Consideration should be given to the fact that tem- perature variations within the wedge or delay line can cause beam angle changes and/or alter the delay on the time base. System checks are typically performed at a minimum of every four hours during the process of examination but can be done more often at the examiners discretion, when malfunc- tioning is suspected.
If during a system calibration check, it is determined that the ultrasonic equipment is not functioning properly, all areas tested since the last successful calibration should be reexamined.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

API 577

What is the distance of eye-to-part to count as a visual exam (NDE)?

A

API 577 (9) Non-destructive Examination

(9. 3) VISUAL EXAMINATION (VT)
(9. 3.1) General
(9. 3.1.e) 6”-24” Direct visual examination requires access to permit the eye to be within 6 in. – 24 in. (150 mm – 600 mm) of the surface, at an angle not less than 30 degrees.