AP Inspiration: Al’s Flashcards

1
Q

Shut down mouthpiece

A

Breathe in
Rotate closed
Remove

Insert
Purge
Rotate open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Diluent flush

A

Primary method:
Manually add dil for 1 sec while inhaling then nose dump; repeat x5

Secondary method:
Pull counterlung dump while manually adding dil for 10-15 sec

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Partial loop flood

A

Shut down mouthpiece
Remove, raise and shake hose to right side (hose higher than shoulder)
Replace mouthpiece

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Bail out

A

Deploy second stage
Shut down mouthpiece
Breath open circuit
Check bailout SPG
Select bailout or low set point on handset
Ascend

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Low O2 warning

A

Check O2 cylinder open
Dil flush or manual add O2
Monitor handset

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

High O2 warning

A

Dil flush
Listen to solenoid
Monitor
Close O2 cylinder if needed

(3 things on left then 1 on right)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Select high setpoint

A

Long push on centre button

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Select low setpoint

A

Long push on centre button

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Complete loop flood

A

OC bailout
Ascend

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Bailout to onboard dil

A

Shut down mouthpiece
Insert AutoAir
Check SPG
Select low set point or bailout
Ascent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Mask clear

A

Minimal bubbles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Remove and replace stage

A

Maintain control of stage
Maintain neutral buoyancy and trim

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Activate backlight

A

Push any button

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

SCR mode

A

Exhale through nose on every third breath
Manually add dil

(Short bursts of dil after nose dump. Could use ADV if task loaded)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Cell warning

A

Perform dil flush to determine correct PO2
Monitor
Consider OCB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

No diluent (confirmed)

A

Start ascent
Consider OCB

17
Q

No O2 (confirmed)

A

Dil flush
SCR Mode
Ascend
Consider OCB

18
Q

Possible elevated CO2 levels

A

Dil flush
Check electronics
Consider OCB

19
Q

Solenoid blocked (closed)

A

Use manual O2 injection
Monitor
Consider OCB

20
Q

Solenoid jammed (open)

A

Close O2 cylinder
Dil flush
Manually control O2 cylinder valve
Consider ascent

21
Q

Full electronics failure

A

Dil flush
SCR Mode
Consider OCB
Ascend

22
Q

Scrubber flood

A

OCB
Ascend

23
Q

Manually add gas with ADV

A

Use left hand
Listen for gas flow

24
Q

Free-flowing ADV

A

Use left hand
Slide flow-stop closed or close dil cylinder
Check ADV/listen

25
Q

BOOM!

(Catastrophic gas loss from an unknown source)

A

Close both cylinders
Check SPGs
Assess which gas has failed
Open good side
Perform no O2 or no dil drill as appropriate.
Thumb dive and ascend

26
Q

Deploy SMB

A
27
Q

Unconscious diver rescue

A
28
Q

Loop volume management

A
29
Q

O2 flush & maintain high O2
(Spike unit)

A
30
Q

Manually maintain a set point of 1.3 with unit on 0.7

A
31
Q

Change Master to Slave
(Low battery)

A
32
Q

Display controller 2

A