all review slide questions Flashcards
Because US pulses are usually 2-3 cycles , axial resolution is usually equal to ______ to ______ wavelengths.
2, 3
4, 6
1, 3.5
1, 1.5
1, 1.5
A two-cycle pulse of 5 MHz ultrasound produces separate echoes from reflectors in soft tissue separated longitudinally by 1 mm.
T/F?
Why?
True
axial res 0.3 mm
5 MHz unfocused transducer
Element width – 13 mm
Near zone length – 14 cm
Lateral resolution is best at what depth?
Lateral resolution at 14 cm is
Lateral resolution at 28 cm is
14
6.5
13
Lateral resolution is improved by: Damping Pulsing Focusing Matching Absorbing
focusing
An unfocused 3.5 MHz 13 mm wide transducer n – 3 cycles AR is this case is better that LR True or false?
True
What Doppler angle yields the greatest Doppler shift? Least Doppler shift? - 90 -45 0 45 90
greatest = 0
least=90
The control that sets the gray-scale brightness below which color will be displayed instead of gray-scale at a pixel location is - Priority Line density Persistence Ensemble length Scale
priority
Color Doppler uses autocorrelation technique to yield what four types of information in real time? Mean Variance Power Sign
mean
In color Doppler instruments, color is used only to represent flow direction in the vessel.
False
Presence
Speed
Character of flow
In practice, approximately _____ pulses are required to obtain one line of color Doppler information?
1 10 100 1000 1,000,000
10 (5-30)
Lack of color in a vessel with blood flow may be attributable to ______ (multiple answers)
Low color gain High wall filter setting Low priority setting Baseline shift Aliasing
Low color gain
High wall filter setting
Low priority setting
Increasing ensemble length ____ color sensitivity and accuracy and ________ FR.
Improves, increases Degrades, increases Degrades, decreases Improves, decreases None of the above
Improves, decreases
What color control helps with clutter?
wall filter
Color map baselines are always represented by what color?
black
Steering the color window to the right or left changes _____
Frame rate PRF Doppler angle Doppler shift None of the above
Doppler angle and Doppler shift
In a single frame, color can be different ( red and blue) in a vessel because of ____
Multiple answers
Vessel curvature
Sector format
Helical flow
Diastolic flow reversal
all
Doppler power imaging indicates the _______ of flow
Presence
Direction
Speed
Character
Answer – presence
If angle correction is set at 0 degrees but should be 60 degrees, the display indicates a flow speed of 100 cm/s The correct flow speed is \_\_\_\_\_ cm/s. 25 50 100 200 400
200
If a 5-kHz Doppler shift corresponds to 100 m/s, a 2.5-kHz shift corresponds to ____ m/s
a. 100
b. 75
c. 50
d. 25
50
Which of the following is increased if Doppler angle is increased?
a. Aliasing
b. Doppler shift
c. Effect of angle error
d. b and c
e. None of the above
effect of angle error
Color-Doppler frame rates are ______ gray-scale rates .
a. equal to
b. less than
c. more than
d. depends on color map
e. depends on priority
less than
Decreased distal resistance normally causes end diastolic flow to ________.
increase decrease be disturbed become turbulent more than one of the above
increase
Flow reversal in diastole indicates ______.
a stenosis an aneurism high distal resistance low distal resistance more than one above
high distance resistance
With angle correct incorporated, higher flow speed always produces a higher Doppler shift on spectral display.
T/F
True