Alarms Flashcards
Which is false about VICADS?
It’s an audio surveillance system
VICADS can be launched by clicking the VICADS personal viewer icon located on camera monitors
True
How do you close VICADS app?
“X” upper right of screen
How are analog video signals converted to digital format so they can be transmitted over the network?
Video encoders
Which tab always you to change the number of screens that can be viewed?
Layout tab
If operators want to view 3 rows of 3 cameras, they select 3x3 plus 1 from the drop down menu under layout tab
False
Camera list contains list of configured cameras that are viewable by operator. To select camera,
Click camera name
Video tours
Tab contains list of configured camera tours for selected camera
To start previously defined tour, left click tour name
Once selected, it will be played
To control a specific camera, select a camera, click padlock, then use cursor to control camera
True
To close a camera
Click “X” upper right
If operators need to reboot a camera, this can be done by
Operators cannot reboot
Operators need to access the on-screen menu of a specific camera,
Click menu tab, click “menu on”
Player panel contains video player windows that allow operators to view pre-recorded video
False
To rearrange video player windows on player panel,
Click video player window you wish to move, left click banner and drag to desired location
Control area is used by operators to
Zoom in, zoom out, pan/tilt camera
Which is false concerning control area?
Selected camera will zoom in or out as long as the right mouse button is held down
As you’re planning or tilting a camera, the pan/tilt speed will decrease as you move the cursor out from center of the grid
False
Control of cameras by multiple users
Message sent to BDOC requesting permission
BDOC gives permission, refuses or ignores
Control is transferred to guests if their requests are ignored by BDOC for 20 seconds
To move camera to previously saved preset,
Left click over preset
Clicking the iris open or close buttons under lens tab
Allows more or less light to enter camera lens
Who is responsible for overall operation of vindicator IDS ensuring proper responses are made to alarms?
FC
Alarm monitor primary functions
Monitoring alarms on the VCC, notifying custodians and dispatching patrols
Alarm monitors must prevent unauthorized personnel from observing actual alarm conditions displayed on monitoring equipment
True
Alarmed facility access authorization letters or EALs must be signed by custodian or higher and authenticated by
20 SFS IDS member
Alarmed facility access authorization letters are used by alarm monitors to
Identify personnel authorized to place IDS in access or secure modes
Contact alarm facility custodian during alarms or other emergencies
Alarm monitors who become aware of outdated Alarmed Facility access authorization letters should notify
20 SFS IDS administrator
Owner/users required to authenticate will do as instructed by alarm monitor who will compare info against the alarmed facility access authorization letters
True
In the event of an invalid authentication,
Dispatch patrols
SF provide alarm monitoring and response to all alarmed facilities but overall responsibility for security of facility/resources lies with
Owner/user personnel
In the event a facility’s IDS fails, owner/user must
Provide security for resources and/or relocate resources to another secure area
_____________ identify the precise location of an event
Status maps
The VCC will automatically display the corresponding alarm point map
Each time an alarm occurs
Alarm monitors may manually display alarm point graphics from the VCC by
Clicking appropriate map responders
____________ houses the V5 or sparrow units, which receive alarm info from the sensor field and send that info to the VCC thru the base unclassified network
Premise control unit
Sensor field typically consists of
Balanced magnetic switches (BMS) Passive infrared (PIR) motion detection sensors Duress switches and other specialized sensors
Which is not one of the four parts of the VCC terminal screen?
Overview map without responders
____________ shows action buttons that allow operators to acknowledge, secure, access and defer alarms
Method toolbar
Events in action list are sorted by priority first, then by time of receipt
False
Which require operators attention?
Intrusion alarms, tamper situations, comm failures
Alarm point list lists all ________ programmed onto system
Alarm points
How can an operator differentiate between active and inactive alarm?
Asterisk for active
What color means secured
Green
What happens when a secure is pending?
Alarm points flash green
What color is for access
Yellow
Which occurred when access is pending
Alarm points flash yellow
During an alarm, alarm points will flash __________ until acknowledged and remain that color until secured
Red
Why is it important to secure alarms after acknowledging?
Alarm points in alarm state will not register subsequent activations
During a thunderstorm, AC power is lost and IDS control panel switches to battery backup power. As long as the uninterruptible power supply is functioning properly, does this automatically constitute a system failure?
No/False
If backup batteries begin to lose power, sporadic alarms will generate from that facility and it will eventually go into
Comm fail
All IDS control panels have an uninterrupted power supply with a minimum of ________ of backup battery power
4 hours
During a comm fail, alarm points will flash ______ until acknowledged and remain that color until comm is restored
Blue
Alarm monitors acknowledge an alarm by using the mouse and pressing the _______ button in the method toolbar
Acknowledge
Alarm monitors secure alarm by using the mouse and pressing the ________ button on method toolbar
Secure
Only the _______ is authorized to secure IDS at a USAFCENT SCIF
Custodian or special security officer
Which compensatory measures are acceptable for IDS failures at pharmacies or medical logistics vaults, AA&E, or funds facilities?
24 hr surveillance
Relocation of resources to another secure facility
Compensatory measures for IDS failures at facilities approved for open storage of classified material may consist of an initial response by owner/user and physical security checks by owner/user every ______ hours
Four
An alarmed facility has inop balanced magnetic switches on the perimeter doors but the motion detection sensors are operational. This is classified as a
Partial failure
If you receive a comm fail alarm that lasts 5 minutes, it constitutes a
Major malfunction
VCC locks up, shuts down and you are unable to restart. This is classified as a
Catastrophic failure
If the IDS at the commissary or an AAFES facility fails, the _______ will conduct a physical inspection of the area with SF
Alarmed facility custodian
If the IDS at the commissary or AAFES facility fails and cannot be secured, an SF patrol will be assigned to conduct physical security checks of the facility, not to exceed
Two hours
Duress alarms indicate a positive duress situation and require a
Immediate response from SF
Tamper alarms indicate what?
Sensor is being tampered with or the PCU enclosure has been opened
Comm failures at facilities other than USAFCENT SCIFs and 20 FW CVN vaults that fail to clear within _______ minutes require an immediate response by SF and custodian must be notified
One minute
False alarms are those which no cause can be determined
True
Which alarms are those caused by an influence the sensor was designed to detect such as animal or an act of nature but is not related to intrusion
Nuisance
If owner/user calls to verify IDS status, the desk must
Ensure caller is on the alarmed facility access authorization list/EAL and authenticate with personnel before giving any info
To ensure proper procedures are followed, alarm monitors must implement and follow
QRCs
Who is responsible for conducting quarterly tests of IDS with SF?
Custodians
The USAFCENT SSO and 20 FW CVN security manager conduct semiannual no-notice exercise at their alarmed facilities. Who do they coordinate with beforehand?
Ops
Operators experiencing problems with VCC should notify the
IDS maintenance personnel
When preparing to test a facility’s IDS, the alarm monitor verified the person calling is authorized to conduct the test by checking the ________ for the facility and authenticate with them
Alarmed facility access authorization letter and EAL