Air Systems Flashcards
Does the isolation valve open if either bleed air switch or air con pack is switched to off?
yes
With the isolation valve switch in AUTO, both bleed air switches ON, and both air conditioning pack switches AUTO or HIGH is the isolation valve open or closed?
Closed
BLEED TRIP OFF Light
illuminated: excessive engine bleed air temperature or pressure
- related engine bleed air valve closes automatically
- requires reset
how to reset = trip reset switch
What systems rely on Bleed Air?
Air conditioning / pressurization wing and engine thermal anti-icing engine starting HYD reservoirs pressurization Water tank pressurization Aspirated TAT probe
PACK (switch)
OFF = pack signaled off
Auto:
- with both packs operating, each pack regulates low flow
- with one pack operating, operating pack regulates to high flow in flight with flaps up
- when operating one pack from APU (both engine BLEED air switches OFF) regulates to high flow
HIGH:
pack regulates to high flow
provides maximum flow rate on ground with APU BLEED air switch ON
With the engine bleed air switch ON, the valve is (BLANK) activated and (black) operated?
DC / pressure
WING-BODY OVERHEAT light (Left or right)
illuminated:
LEFT light indicates overheat from bleed air duct leak in left engine strut, left inboard wing leading edge, left air conditioning bay, keel beam or APU bleed air duct
RIGHT light indicates overheat from bleed air duct leak in right engine strut, right inboard wind leading edge or right air conditioning bay
PACK (light)
Illuminated:
- indicates pack trip off or failure of both primary and standby pack controls
- during master caution recall, indicates failure of either primary or standby pack control. extinguishes when master caution is reset
The Duct pressure indicator is powered by what electrical?
AC
The isolation valve is powered by what electrical ?
AC
ISOLATION VALVE (switch)
Close = closes isolation valve
AUTO:
- closes isolation valve is both BLEED air switches are ON and both air conditioning PACK switches are AUTO or high
- opens isolation valve automatically if either engine BLEED air or air conditioning PACK switch positioned OFF
Open = opens isolation valve
DUAL BLEED (light)
Illuminated:
APU bleed air valve open and engine NO.1 BLEED air switch ON or engine NO.2 BLEED air switch ON
APU bleed air valve and isolation valve open
Is a single pack capable of maintaining max pressurization and acceptable temperatures up to max certified ceiling?
YUP