Air Starting System Flashcards
1
Q
What are three maintenance procedures for main starting air compressors?
A
- Regular replacement of air suction filter
- Clean air cooler
- Overhaul valves as per running hours
2
Q
What is the procedure for manual starting of a compressor?
A
- Ensure that there is sufficient oil within the sump
- Ensure that cooling water is open
- Ensure stage drains and discharge valves are open
- Press start
- Check running amps
- Once up to speed, close all stage drains and de-loading valve
- Check pressure build up in air bottles
3
Q
How can deterioration in the efficiency of a compressor be detected?
A
- Increased running time when filling bottles
- Abnormal differential between suction and discharge pressures
- Low pressure at outlet
- High running amps
- High air outlet temperature
- Cooling water temperature increase
- Oil consumption increase
4
Q
What are four causes for deterioration in efficiency?
A
- Worn or damaged suction and discharge valves
- Soiled air intake filters
- Damaged piston rings and barrel
- Dirty coolers
5
Q
What is a test for establishing compressor performance?
A
- Measure the time taken to fill a reservoir and compare this against another compressor (25 bar)
- Mathematically work using manufacturer’s data, using this theoretical value as a benchmark
- If one compressor takes longer, it could indicate it is less efficient