Air Conditioning/Pressurization/Ventilation/Pneumatic Flashcards

A320 S-LOD

1
Q

Air-002
Recall the Function of each position of the x bleed selector.

A

-Shut
*commands crossbleed valve closed, overriding auto logic.
-Auto:
*auto logic controls open and closing of the crossbleed valve
*crossbleed valve commanded open when the APU bleed Valve is open
*crossbleed valve commanded closed when APU bleed valve is closed.
*crossbleed valve commanded closed when a bleed leak is detected.
-OPEN_
*commands the crossbleed valve open, overriding the auto logic.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

AIR-004
Recall the indication of external high-pressure air being applied to the pneumatic system.

A

With NOinternal air source being provided(I.E. APU or engine bleed air) , A PSI Value is displayed on the left side of the ECAm Bleed page. By default, the air source must be external high pressure air cart.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Air_005
Recall the indications of the Engine bleed valve and HP(High Pressure ) valves on the ECAM Bleed Page.

A

*ENGINE BLEED VALVES are depicted next to the respetvie engine’s number(1 and 2) on the lower portion on the page.
*HP valves are depicted on the lower portion of the page next to the white HP designator.

NOTE: IP(intermediate pressure) check valves are not specifically depicted but are represented by white IP designator.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

AIR_008
Recall the Indication when the APU bleed air is in use

A

*APU bleed valve indicates open on the ECAM bleed page.
*APU Bleed is displayed in green on the memo section of the E/WD.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Air_009 Recall the areas of the aircraft where a bleed air leak can be detected.

A
  • WINGS:each wing’s bleed air duct
    *Engine Pylons: area from the engine to the respective wing bleed duct
    *Aft Fuselage: area surrounding the APU Bleed air duct
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Air_011 Recall the indications and effects of Zone Controller channel Failures.

A

*Primary Channel Failure
_Alt Mode appears at the top of the ECAM Cond Page
-Secondary channel operates as backup.
-flow setting function and optimized temp function are not available.
-HOT AIR and Trim Air valves close.

*secondary Channel Failure:
-Has no effect on zone temperature regulation
-backup mode is lost.temperature indications are lost.
*Primary and Second channel Failure:
-PACK REG appears at the top of the ECAM cond page.
-removes all information from ecam cond page.
-Optimized and backup temperature regulations loss
-packs deliver a fixed temperature.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Air-013 Recall the effect of Air Condition pack controller channel failures

A

*Primary Channel Failure:
-Secondary channel Operates as backup.
~pack flow is fixed at previous stetting.

*Secondary Channel Failure:
-Has no effect on packflow regulation.
~backup mode is lost
~ECAM indications related to corresponding pack are lost

*Primary and Secondary Channel Failure:
-Pack outlet temperature is controlled by the anti-ice valve.
~outlet temperature is stabilized
~ECAM indications related to the packs are lost.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly