AdjdjdjdjMdjriwpqpGbxjdj Flashcards

1
Q

Patriot units require a minimum of_______ hours daily of maintenance.

A

4 Hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many personnel are required to perform PMCS on the EPP III generators ?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is Patriot Prime Power ?

A

120/208 VAC , 3 Phase , 400 Hertz

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Park the truck with the EPP III at a suitable location so that it’s distance from the ECS and RS does not exceed the available length of cable on the EPP III drums approximately _________ feet.

A

75

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the first step in normal shutdown for the 150 Kw EPP III generator ?

A

Press AC circuit Interrupter OFF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Describe the 3 classes of leaks

A

Class I
A minor leak is indicated by wetness or discoloration, but not enough to form drops.
Class II
A minor leak that is indicated by drops that form, but not enough to drip from the item being inspected.
Class III
A critical leak that is indicated by drops that form and fall from the item being inspected.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How are the AMG masts elevated to the vertical position?

A

Hydraulically

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the approximate maximum height of the AMG masts ?

A

81 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the max tolerance for level and cross-level for the AMG ?

A

10 degrees cross roll and 1/2 degree roll

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What device is used to obtain the AMG vehicle heading ?

A

Compass

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When lowering masts , a safety switch automatically stops masts from moving lower than _____ degrees ?

A

10 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How are the AMG masts elevated to the horizontal position ?

A

Pneumatically

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How many antenna assemblies are on each of the telescoping masts of the AMG ?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How long does the AMG crew have to install guy wires ?

A

Not timed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

During high winds , AMG mast must be retracted when ?

A

All the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where are the AMG controls and indicators for mast warning lights and fault lamps located ?

A

Distribution Box

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What Basic gunnery table covers PMCS ?

A

Table I

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

During extended emplacements some settling may occur. RS roll and cross-roll should be checked every _____ hours. A difference of 2 mils or more may result in radar missile acquisition failure and subsequent missle self- destruct and/or track correlation failure

A

24 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the radiation hazard distance in front of the radar ?

A

120m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

If the RS is to be powered down for more than 2 hours , all shelter doors and air doors MUST be closed

A

True

21
Q

What is the nomenclature for the SEMITRAILER , FLATBED : RADAR SET ?

A

M860A1

22
Q

The patriot radar ______ , ________ , and _________ targets ?

A

Detects , Tracks , Identifies

23
Q

What should the operator do if the kingpin is not secure in the M983 coupler jaws ?

A

Rock the HEMMT back and forth until the fifth wheel is locked

24
Q

Who is responsible for draining the semitrailer air tank during automatic emplacement of the RS ?

A

CM 3

25
Q

When leveling the RS at least ______ semitrailer wheel on each side must be off the ground ?

A

1

26
Q

The Azimuth Drive Local Control (ADLC) is used to position the Radar shelter in the azimuth during the local mode of operation

A

True

27
Q

How many aiming circles are required to perform manual emplacement on the RS ?

A

Two aiming circles

28
Q

To prevent equipment damage when raising outriggers , ensure outrigger pads have _______ all the way to the stow position.

A

Free Movement

29
Q

What encryption device plugs into the Air Defense Interrogator ?

A

KIV77

30
Q

What power is needed to operate the outriggers of the M860 SEMITRAILER ?

A

24 VDC

31
Q

What coolant does the AN/MPQ-65 ( Radar Set) use ?

A

Ethylene Glycol

32
Q

Equipment must be separated by _______ cable distance ?

A

Maximum

33
Q

What does PDB stand for ?

A

Post Deployment Build

34
Q

Which alert states require full manning ?

A

1-4

35
Q

A fire unit has _____ minutes to achieve minimum engagement and ____ minutes to be IAW the STO

A

Minimum Engagement - 45 min
Green Bar ( STO) - 60 min

36
Q

What is an example of active Air Defense Measures ?

A

Measure taken to destroy enemy aerial objects in flight

37
Q

What is an example of passive Air Defense Measures ?

A

Cover and concealment , limiting radio frequencies , site hardening.

38
Q

How many alert states are there, and what are they ?

A

8 alert states
0.IN-TRANSIT(MOVING)
1.ABT
2.TBM
3.PASSIVE SEARCH
4.RADIATE DISABLE
5.COMMANDERS DISCRETION
6.MAINTENANCE
7.NMC/DESTROYED

39
Q

Define all Air Defense Warnings (ADW)

A

ADW WHITE: ATTACK NOT PROBABLE
ADW YELLOW: ATTACK PROBABLE
ADW RED: ATTACK IMMINENT or IN PROGRESS

40
Q

Define WCS Hold:

A

Units may only fire in self-defense or when ordered by proper higher authority

41
Q

Define WCS Tight:

A

Only targets positively identified as hostile may be engaged

42
Q

Define WCS Free:

A

Any target not positively identified as friendly may be engaged

43
Q

As part of your March Order drill , you should allow the generator to run at no-load for _____ minutes to cool down the engines

A

5 mins

44
Q

How long can a generator set run operating on a full load when it has a full fuel tank ?

A

10 hrs

45
Q

How often should your EPP III generators be load banked ?

A

Semi-Annually

46
Q

What is the length of the four EPP power cables ?

A

95 ft

47
Q

In the case of an emergency such as a fuel spill what is the procedure for emergency Shutdown of the EPP III

A

Remove key from master switch

48
Q

What maintenance form is used for PMCS ?

A

5988

49
Q

Do not apply power unless voltage switch is set to L1 , wait _____ before applying power.

A

30 seconds