ACS examination prep Flashcards
How do you convert Gross Kw into Net Kw?
Heat input (Kw gross)/ 1.11
How do you convert from heat input into flow rate (m3/h)?
(Heat input (kw) x 3.6)/38.9
What is RIDDOR reportable as a gas engineer?
Anything classed as immediately dangerous
When did the Gas safe register become the official governing body?
1 April 2009
What is GSIUR 1998?
Gas safety installation and usage regulations
What are the Gas safety (management) regulations? (A to D)
A- Safe management of Gas flow through a network supplying domestic consumers
B- Arrangements for dealing with supply emergencies
C- Arrangements for dealing with gas escapes and incidents
D- Composition of Gas
Who has right of entry according to Gas safety regulations?
Gas transporter
What is the process for RIDDOR reporting?
Notify the HSE and fill in online form within 14 days
What is the installation volume made up of?
IV of meter + IV of pipework + IV of fittings
How do you calculate Purge volume?
1.5 x Installation volume
What is the maximum installation volume allowed?
0.035 m3
What is the maximum operating pressure on the outlet of the meter?
21 +/-2 mbar
What is the maximum incoming mains gas pressure on the inlet to the meter?
2 bar
What are the pressures for intermediate gas mains?
2-7 Bar
What are the pressures for Medium gas mains?
75mbar- 2 Bar