AC Panel Switches Flashcards

1
Q

Equip Cooling
AUTO

A

Auto controls equipment cooling mode.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Equip Cooling
OVRD

A

A. Extinguishes both cooling fans
B. Override Valve Open
C. Forward Cargo Heat valve closed.
D. OVRD light illuminated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Equip Cooling
OVRD

A

(Amber)
Equipment cooling override valve open.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Gasper Switch
ON

A

Operates Gasper Fan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Gasper Switch
OFF / Blanked

A

Shuts off Gasper Fan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Recirc Fans Upper Lower
ON

A

Automatically operates associated recirculation fans.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

FLT DECK TEMP Control
AUTO

A

Automatically controls temperature for flightdeck.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FLT DECK TEMP Control
C/W

A

Sets desired temperature between 65 and 85 F. (18/29 C)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

FLT DECK TEMP Control
MAN

A

Provides Manual control of flightdeck trim air valve.
Turning to C drives trim valve colder.
Turning to W drives trim valve warmer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Cabin Temp Control
C/W

A

Sets cabin master reference temp between 65 and 85 F. (18/29 C )

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

AIR COND RESET

A
  1. Resets any closed pack flow control valves or trim air valves.
  2. Attempt to reset failed recirculation fan.
  3. Reset Fault Protection.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

L/R Pack Switches
Auto

A

Automatically controls pack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

L/R Pack Switches
Off (Blank)

A

Closes pack flow control valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

L/R Pack Switches
Off (Amber)

A

1.Pack flow valve failed closed
2.Pack High Temperature occurred
3.Bleed air pressure inadequate.
4. R Pack valve closed during APU to Pack takeoff procedure.
5. Pack switch pushed off.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

L/R Trim Air Switches
ON

A

Opens Trim Air Valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

L/R Trim Air Switches
Fault

A

1.Trim air valve failed closed.
2.Trim air valve closed due to zone supply duct overheat.
3.Trim Air Switch off.

17
Q

PACK MODES

A

NON-NORMAL AND STANDBY cooling

18
Q

STANDBY MODE

A

WARMER TEMPS AT LOWER ALTITUDES