8 - Internal Forced Convection Flashcards
What tube shape gives the most heat transfer for the least pressure drop, withstanding large pressure differences between the inside and outside without significant distortion?
Circular
What is the irrotational (core) flow region?
The frictional effects are negligible and the velocity remains essentially constant in the radial direction.
What is the boundary layer region?
The viscous effects and the velocity changes are significant.
What is the hydrodynamic entrance region?
The region from the pipe inlet to the point at which the velocity profile is fully developed.
What is the hydrodynamic entry length?
The length of the hydrodynamic entrance region.
What is the hydrodynamically fully developed region?
The region beyond the entrance region in which the velocity profile is fully developed and remains unchanged.
What is the bulk mean fluid temperature?
The arithmetic average of the mean temperatures at the inlet and the exit.
What is the thermal entrance region?
The region of flow over which the thermal boundary layer develops and reaches the tube centre.
What is the thermal entry length?
The length of the thermal entrance region.
What is thermally developing flow?
Flow in the thermal entrance region, where the temperature profile develops.
What is the thermally fully developed region?
The region beyond the thermal entrance region in which the dimensionless temperature profile remains unchanged.
Define fully developed flow
The region in which the flow is both hydrodynamically and thermally developed.
What are the friction and convection coefficients in the fully developed region of a tube?
Constant (i.e. do not vary with x).
What are the properties and effect of the entrance region?
Properties are higher pressure drop, heat flux, Nusselt number and h values.
Effect is to increase average friction factor and heat transfer coefficient for the whole tube.
When can the flow be assumed to be fully developed?
When x > 10D, as the Nusselt number reaches a constant value at a distance of less than 10 diameters.