737 Flashcards
737 Evac Routes Land
All exits
737 Evac Routes Belly
All exits
737 Evac Routes Water
Doors 1 and overwing exits only
AFT doors are NOT to be opened as they are expected to be just BELOW the water line
737 Overwing Window Exit
4 overwing window exits
Open out and up automatically once the handle is pulled
The overwing window exits are not fitted with slides (no manual inflation handle)
737 Evacuation Ropes
Located in the upper frame of each aft overwing exit
737 Emergency light button location
L 2
737 Emergency Call to flight deck
Dial ALERT code (222) on any handset
737 Galley Emergency Power Shut-off
Contact FD
737 Designated Fuelling Emergency Exits
L1 and L2 or R2
737
Oxygen Mask Deployment Failure Passenger seats Lavatories
Insert a hair pin or pointed side of the oxygen release rod in the pin hole of the panel
737
Oxygen Mask Deployment Failure /
Cabin crew jumpseats
Insert the flat surface of the rod or any flat object in the panel and pull down
737 Oxygen Release Rods location
Located under L1 and L2 jumpseats
737 Cabin doors
No power assist when opened in armed mode
Do not disarm automatically when opened from the outside
Armed indicator Girt bar secured in floor brackets
Disarmed indicator Girt bar is secured in stowage hooks on slide container
Red warning strap indicates to anyone on the outside that the door is armed it must be placed across the window when the slide is armed
737 Location of Survival Kits
Embedded in the life-rafts
SSKs are located in the vicinity of L1 and OR