7. Controlling Utilities And Building Systems Flashcards
And a working structure fire_____is one of the best ways in which to protect firefighters and occupants may be trapped inside.
Securing the building’s utilities
Page 177
These handheld devices not only detect the presence of combustible gas, they also indicate its concentration. Some of these units express gas detected in parts per million and others as a percentage of the lower explosive limit.
Combustible gas indicator’s
P186
The other way that firefighters may help reduce the hazard of the fuel gas leak is by systematically eliminating source of ignition downwind of the leak. This is usually done in areas from which the occupants have been evacuated. Starting from a point within the perimeter that is______from the leak.
Farthest
P188
Where power is distributed to the neighborhood through overhead wires from the power grid, buildings main electrical panel is usually located ______where power from a pole mounted transform into the building.
Directly below the weatherhead
P189
Storage batteries are a source of flammable ______
Hydrogen gas
P190
Came to check unshielded AC current through snow, ice, and many solid objects.
Alternating current detectors
P194
Occurs when an insulated conductor is in contact with the ground or there is a kink or damage to the conductor, insulated or not.
Resistance