5 Eat 17 Flashcards
Speed of an actuator may be regulated with a _____ _____ valve
Flow control
When the flow control valve controls the amount of oil going into the actuator, the application is _________.
Meter-in
In applications where the load might tend to “run away” the flow control application should be ________.
Meter-out
When the flow control os teed off the supply line from the pump and determines the actuator speed by metering a portion of the pump delivery to the tank, the application is called _____.
Bleed-off
The light spring in a by-pass type flow control holds the pressure compensator normally ______.
Closed
The light spring in a restrictor type flow control valve holds the pressure compensator normally ______.
Open
Flow through a pressure compensated flow control valve is subject to change with variations in oil ______.
Temperature
Deceleration valves are usually uses in a meter-out configuration (T or F)
True
The use of a proportional valve requires the equipment contain _______ controls.
Electronic
This graphic symbol depicts what kind of valve?
Meter-in restrictor type