When is RIT mandatory
Full assignments or greater
Who forms RIT group
4th engine, 2nd ladder
Who is primary RIT
Squads
How many minutes is RIT SCBA bottle
60
How many feet apart are the rings
20
How many feet of rope for RIT
200
What blade is on the rescue saw
D’ax
How many chainsaws are provided
2
What blades are provided with the Sawzall
Wood and metal cutting
Who is usually the RIT group OIC
Ranking squad officer
Where is RIT tag placed
On pump panel
What talk group is assigned for RIT ops
2nd expansion group
How many members make up RIT Recon
3-4
What type of approach is used for access
6 sided
What channel does the IC move tac ops to
1st expansion group
What entry point should he used
C
Q
S
What should be placed at the entry point
Bright light
What does LIP stand for
L
I
P
What channel does the downed FF stay on
Talk group
How is the 2nd RIT team set up
Opposite the 1st
What is the most important action
Maintain air supply to downed FF