320 Flashcards
On the A321, where is the manual inflation handle for doors 2 and 3?
- On the right hand side of the girt apron
- On the forward end of the gift bar under a plastic cover
- At floor level by passenger 11F
- Upper right hand side of the door frame under plastic cover
Upper right hand side of the door frame under plastic cover
If the ‘CAUT’ button illuminates on the FAP, how is it reset?
- Press the ‘RESET’ button
- Press ‘RESET’ and ‘CAUT’ at the same time
- Press and hold the ‘CAUT’ button for 5 seconds
- By pressing the ‘CAUT’ button
By pressing the ‘CAUT’ button
If smoke is detected at the front of the cabin, where is the nearest BCF/ HAFEX?
- In the left hand overhead locker
- Under the forward cabin crew seats
- On the forward galley top
- In the wardrobe in the forward galley
Under the forward Cabin crew seats
At what cabin altitude, approximately, will the seat belt and Exit signs illuminate?
- 10,000 Feet
- 11,500 Feet
- 9000 Feet
- 14,000 Feet
11,500 Feet
What is the procedure of activating/deactivating the PED Power on a NEO aircraft?
- It must be switched off during turbulence
- It activates/deactivates automatically as the aircraft passes 1000ft
- There is no requirement to turn it off as passengers use electronic devices at any time
- It must be switched off for TTL (Taxi, Take-off and landing)
It must be switched off for TTL (Taxi, Take-off and landing)
What position must the swivel seat be in when not occupied?
- It must be open and available for use
- It must be stowed when not in use
- It must be ready for use in case of turbulence
- It must be open but the seat pan left closed
It must be stowed when not in use
What piece of SEP equipment is stowed under every crew seat?
- A megaphone
- A lifejacket (life vest)
- A BCF/HAFEX
- A portable oxygen bottle
A lifejacket (life vest)
At approximately what cabin altitude will the oxygen masks drop automatically, in a decompression?
- 11,000 Feet
- 14,000 Feet
- 11,500 Feet
- 10,000 Feet
14,000 Feet
If triple chimes sound in the cabin, repeated every 30 seconds, what is happening?
- Smoke has been detected in a toilet
- There is a medical emergency
- There is a potential breach of the flight deck
- The aircraft has suffered a decompression
Smoke has been detected in a toilet
During normal opening, why is it necessary to pause the control handle when resistance is felt?
- to check the White Slide Armed light is not on
- to check the green locking indicator
- To check the EXIT lights are not illuminated
- To check the manual indicator is not flashing
To check the White Slide Armed Light is not on
How are the Flight Crew informed that cabin and galley checks are complete, if there is no Cabin Secure Indicator (CSI) fitted?
- Knocking on the flight deck door three times
- By visiting the flight deck in person
- Pressing the ‘cabin ready’ button on the enhanced touch screen FAP
- An interphone to call the Flight Crew
Pressing the ‘cabin ready’ button on the enhanced touch screen FAP
The pre-flight check on a door includes that it is properly closed and what else?
- Red pressure light is extinguished
- The door is manual/disarmed
- The window is clean
- White slide armed light is extinguished
The door is in manual/disarmed
What must a crew member check at floor level to confirm automatic mode?
- There are no extra checks at floor level for any door
- That the girt bar is visible
- The word ARMED is illuminated
- Disc is aligned with the arrow by the word ‘ARMED’
Disc is aligned with the arrow by the word ‘ARMED’
Where is the water extinguisher stowed?
- Rear of the aircraft on the right or left hand side
- On the flight deck right hand bulkhead
- On the flight deck left hand bulkhead
- In the forward galley on the left hand side
Rear of the aircraft on the left or right hand side
Where is the PED button located?
- In the flight deck
- Adjacent to the IFE
- FAP - hard let or power toggle switch in overhead panel
- There is no requirement for one
FAP - hard key or power toggle switch in overhead panel