3 Flashcards
Major contributors to foodborne illness
- Improper holding temperatures 37%
- Poor personal hygiene and improper handwashing 19%
- Contaminated equipment 16%
- Inadequate cooking 11%
- Food from unsafe sources 6%
- Other 11%
temperature abuse
β’ Exposed to temperatures in the temperature danger zone
β’ Not cooked or reheated sufficiently
Thermometers, thermo-couples
π«
measure temperature of stored, cooked, cooling, hot-heldβ¦
food temperature-measuring device with small diameter probe
thin foods, such as: meat patties, fish filets
(Thermometer) Dial-face, metal stem
Most common type of thermometer used
type (bi-metallic)
- measure internal food temperature at every stage
in the flow of food - Measures temperatures ranging from 0β (-18β) to
220β (104β) with 2β increments - Stem of bi-metallic thermometer must be inserted at least
2 inches into the food item being measured
Digital
- Displays temperature numerically
- Measures wider range of temperatures
Thermocouple
- digital readout of temperature
- interchangeable probes
- Sensing portion is often at the tip of the probe
Infrared
- surface temperature of food without touching the food
- 20 minutes to adjust after use for hot and cold temperatures (βThermal shockβ) before use
- Accuracy must be checked frequently
T-Sticks (melt devices)
- Measure only one temperature
- Change color when indicated temperature is reached
- Used to monitor food temperatures and sanitizing temperature in dishwashing machines
Maximum Registering (holding)
- temperature of hot water used to
sanitize items in mechanical warewashing machines
Before you use a thermometer
calibrate it or make sure it is working correctly.
Calibrate means to
compare and adjust with a known standard.
Dial-face metal stem type (bi-metal thermometers should calibrated
β’ Before first use
β’ regular intervals
β’ If dropped or otherwise damaged
β’ If used to measure extreme temperatures
β’ Whenever accuracy is in question
Boiling Point Method
2 inches of stem from the tip (the sensing part of the probe) into
boiling water and adjust the needle to 212β (100β).
Ice Point Method
Insert probe into a cup of crushed ice.
Add enough cold water to remove any air pockets that might remain.
Wait until the temperature stabilizes and adjust the needle to 32β (0β).
Measuring Food Temperature
- sensing portion of a food
- thermometer is at the end of the stem of probe.