21-30 PLUMBING FIXTURES Flashcards
Receptacles which are used to provide, receive and discharge water, liquid and water-carried wastes into a drainage system with which they are connected.
Plumbing Fixtures
- Soil
- Scullery
- Bathing
Plumbing Fixtures
Water Closets
Soil Fixtures
Slop Sinks
Soil Fixtures
Urinals
Soil Fixtures
Kitchen Sinks
Scullery Fixtures
Laundry Tubs
Scullery Fixtures
Bar Sinks
Scullery Fixtures
Lavatories
Bathing Fixtures
Bathtubs
Bathing Fixtures
Shower Baths
Bathing Fixtures
Bidets
Bathing Fixtures
Foot/Sitz Tub
Bathing Fixtures
Shower Receptors
Bathing Fixtures
Shower Compartments
Bathing Fixtures
Setting:
- Water closet center to side wall: minimum of 0.375 m
- Water closet center to WC center: minimum of** 0.75 m**
WATER CLOSETS
Setting:
* Urinal center to side wall: minimum of 0.30 m
* Urinal center to urinal center: minimum of 0.60 m
Flushing:
* Flushing urinals shall be done through automatic flushing tanks. (NPC 408.1)
* Flushometer valves shall be self-closing type discharging a predetermined quantity of water. No manually controlled flushometer valve shall be used to flush group urinals. (NPC 408.2)
URINALS
Materials:
* Stainless Steel
* Cast Iron Enamel
* Formed Steel Coated with Porcelain Enamel
* Single, Double or Triple Well, Shallow and Deep well, etc.
KITCHEN SINKS
Materials:
* Cement or Cement with Tiles
* Porcelain
LAUNDRY TUBS
Where janitors clean & leave their mops
SLOP SINKS
- with removable panel of sufficient dimension to access pump
- circulation pump shall be located above the crown weir of the trap
- pump and circulation piping shall be self draining
WHIRLPOOL BATHS
- Brand Name of luxury type bathtubs
JACUZZIS
- Used for cleaning private parts
- Sometimes referred to as female urinals
BIDETS
- With approved-type hinged strainer plate having the sum of the areas of the small holes of the waterway equal to the crosssectional area of the tailpiece
- Provided with integrally cast water stop outside flange around the body at mid depth and with an inside caulk outlet to provide a watertight joint in the floor
FLOOR DRAINS
- Receptor floor shall drain not less than 2% or more than 4% slope.
- Thresholds shall accommodate a minimum 559 mm wide door.
- For wheelchair use, dam or curb may be eliminated.
SHOWER RECEPTORS
- Metal enclosure containing shower head, valves and faucets
- Shall have a minimum interior area of 0.6 sqm and shall be capable of encompassing a 762 mm diameter circle.
- This area shall be maintained from a point above the shower drain to a height of 1.78 m with no protrusions other than the fixture valve, shower head and safety grab rails.
- Drains for gang shower rooms shall be spaced not more than 4.9 m apart.
SHOWER BATHS/ COMPARTMENTS