describe two critical properties to be considered in the selection of polyethylene as a bearing material in this prosthetic device
resistant to wear
needs to be able to withstand impact and shock
reduce friction between titanium supports
all implant materials must be bio-compatible
what does bio compatible mean
not harmful or toxic to living tissue.
Describe, with the aid of a diagram a mechanical test suitable for measuring the hardness of titanium
Vickers test for hardness
indenter is pressed against the surface of the test specimen
The softer the material is the deeper the indentation will be
outline 2 reasons why non-destructive tests are used during the manufacture of an engine crankshaft
it doesnt destroy the piece
it costs less
describe, with the aid of a diagram the principle of eddy current testing
Coil with high frequency alternating current is placed next to conductive material
Eddy current is induced in material
Currents produce magnetic field in test material
Search coil is connected to an electronic reading device
Any defect in material distorts magnetic field and is indicated on the recording device
what is a suitable application of eddy current testing
the detection of surface or sub-surface flaws in non ferrous metals.