2 - LM2500 GTE Base and Enclosure Assembly Flashcards

1
Q

LM2500 Module/Base Enclosure Assembly

A

Provides a controlled operating environment for the GTM

Also provides thermal and acoustic protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Thermal and acoustic protection

A

Provided by:
3/8” thick steel outer walls
4” of fiberglass insulation
Perforated metal wall; 2000 F for 15 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Fire Detection within the module

A

3 UV flame detectors
Flame detector signal conditioner
2 temperature switches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Fire Extinguishing methods

A

Two 95-lb Halon bottles
Two CO2 actuation bottles-30sec time delay
Directional control valve
Two discharge nozzles in the GTM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Externally-mounted cooling fan

A

Forces air down through the vent damper, around the engine, and out through the exhaust eductor
Cooling fan starts automatically after engine start and secures 10 min after engine shutdown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Vent Damper

A

Pneumatically opened via a solenoid during start sequence
Upon loss of Low Pressure control air, the damper fails in its open position
Can be cycled manually in an emergency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Enclosure heater

A

Keeps GTM warm enough to prevent waxing of the fuel and ensures proper fuel viscosity
Heater elements turns on at 60F-70F; turns off at 85F-95F
Fan energizes between 120F-130F; de-energizes at 145F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Ice Detector

A

Located inside the inlet plenum
Alarms sound when Relative Humidity increases to 70% or more, or temp. decreases to 41F or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly