2 LE RISQUE ELECTRIQUE 1 Flashcards
TENSION COURANT ALTER
- TBT = T INF A 50
- HT = T ENTRE 50 ET 1000
- THT = T SUP A 1000
TENSION COURANT CONTINU
- TBT = T INF A 120
- HT = T ENTRE 120 ET 1500
THT = T SUP A 1500
FUMEE FEU ELECTRIQUE
ACRE ET TOXIQUE
FEU BT LE PORTE LANCE AGUERRI DOIT
- MANOEUVRE DE LA ZONE SANS RISQUE ET DIRIGER SON JET PAR PRECAUTION SUR LES PIECES SOUS TENSION
- GESTES LENTS ET PRECIS
- RECULER A LA MOINDRE SENSATION DE PICOTTEMENS
- ATTENTION AU RISQUE D ELECTRISATION EAUX DE RUISSELLEMENT
- VIGILANT AUX PIECES METALLIQUE
FEU HT
IMMIEDIATEMENT
DDE ERDF EN PRECSIANT FEU D INSTALLATION HAUTE TENSION
FEU HT
EXTINCTION
AUCUNE EXTINCTION NE DOIT ETRE ENTREPRISE AVANT LA MMISE HORS TENSION DE L ENSEMBLE PAR DU PERSONNEL QUALIFIE
FEU HT
SI ETABLISSEMENT DE MOYENS HYDRAULIQUE
ATTENTION A CE QUE L EAU NE RENTRE PAS EN CONTACT AVEC D AUTRES ENSEMBLE OU DU PERSONNEL;
FEU INSTALLATIONS ELECTRONIQUE
- GAZ INERTE
- MOYEN PORTATIF
- DERNIER RECOURS L EAU PAR PETITE QUANTITE
SI RECO !!!! ARI ET CONTROLE DE L ATMOSPHERE
INTERVENTION RESEAU FERRE
INTER SUR VOIES AVEC LAC
DISTANCE DE SECURITE DE 3 M DES CATENAIRES TANT QU ON A PAS LA CERTITUDE QUE LE COURANT EST COUPE
INTERVENTION RESEAU FERRE
DANS TOUS LES CAS IL FAUT
- MESURES DE SECURITE DU BSP 370
- NE JAMAIS TOUCHE DE CATENAIRES CHUTES NI AUTRES PIECES EN CONTACT AVEC CELUI CI
- NE PAS MONTER SUR LES POTEAUX
- NE PAS SE LIVRER A DES TRAVAUX SUR LES PIECES SOUS TENSION OU TROP PRES
- SE MEFIER DU COURANT DE RETOUR ET DES COURANTS INDUITS AINSI QU AUX AMORCAGES
- TENIR COMPTES QUE LES GAZS CHAUDS ET FUMMEE SONT CONDUCTEURS
- S ASSURER QUE LES ECHELLES ET OUTILS EMPLOYES NE RENTRENT PAS EN COTACT OU TROP PRES DES INSTALLATIONS
DISTANCE D AMORCAGE ARCS ELECTRIQUE
40 CM