2. Fittings. Flashcards
- Caulking ferrule specifications:
Pipe size - inside diameter - length - minimum weight?
2” - 2-1/4” - 4-1/2” - 1 lb.
3” - 3-1/4” - 4-1/2” - 1 lb. 12 oz.
4” - 4-1/4” - 4-1/2” - 2 lb. 8 oz.
1 Stand pipe fittings requirements.
Fittings shall be extra-heavy pattern where pressures exceeds 175 psi.
- Soldering bushing specifications:
pipe size - minimum weight?
1-1/4" - 6 oz. 1-1/2" - 8 oz. 2" - 14 oz. 2-1/2" - 1 lb. 6 oz. 3" - 2 lb. 4" - 3 lb. 8 oz.
- What are the basic elements of directional and branch fittings?
See figure # 21.
- Name of 11.25, 22.5, 4t5, 60, 72* fittings?
11.25* - 1/32 bends, 22,5* - 1/16 bends, 45* - 1/8 bends, 60* - 1/6 bends, 72* - 1/5 bend.
6 Name of fitting on figure 91.
Increaser.
- Name of fitting on figure 95.
Vent branches, single.
- Take offs for 1/2” and 3/4” copper for 90* and 45* ells?
1/2” 90d: 3/8”,
1/2” 45: 1/4”,
3/4” 90s: 1/2”,
3/4” 45: 3/8”.
- Clean out on the dead end of the pipe?
Ferrule C O.
14. Soldering bushings. Made of - ? Diameter - ? Minimum weight of 1-1/4" - ? 1-1/2" - ? 2" - ? 2-1/2" - ? 3" - ? 4" - ?
Made of - Red brass.
Diameter - 1-1/4”, 1-1/2”, 2”, 2-1/2”, 3”, 4”..
Minimum weight of 1-1/4” - 6 oz.
1-1/2” - 8 oz.
2” - 14 oz. . 2-1/2” - 1 lbs. 6 oz.
3” - 2 lbs.
4” - 3 lbs. 8 oz.
15. Caulking ferrule: Made of - Diameter - Inside diameter - Length - Minimum weight of 2" - 3" - 4" - ?oz.
Made of - Red brass.
Diameter - 2”. 3”. 4”.
Inside diameter - 1/4” larger of nominal size.
Length - 4-1/2”.
Minimum weight of 2” - 1 pound.
3” - 1lb. 12 oz.
4” - 2 lb. 8 oz.
- What kind of mechanical fittings does law 99/2009 allow to use on water distribution piping?
Crimping fittings.
- Fitting for brazing joints?
- Commercially available short-cup brazing fittings.
2. For copper tube also standard solder-type fittings.
- Fittings for change in direction of drain line.
- Horizontal to vertical, vertical to horizontal, horizontal to horizontal.
- Only horizontal to vertical.
- Horizontal to vertical, but for V to H and H to H permitted for a 2-inch or smaller fixture drain.
- H to V, V to H permitted for a 2-inch or smaller fixture drain and 3” or larger fitting, H to H permitted for 2-inch or smaller fixture drain.
1. Sixteen bend. Eight bend. Sixth bend. Long sweep. Wye. Combination wye and eight bend. 2. Sanitary tee. 3. Quarter bend. 4. Short sweep.
- Types of closet flanges?
- Instant set closet flange.
- Closet flange, notched and slotted.
- Greensboro reducing closet flange.
- Offset closet flange.
- Types of eight bend?
- Eight bend.
2. Long eight bend.
- Types of long sweep?
- Long sweep.
2. Reducing long sweep.
- Types o fcombination?
- Combination.
- Extended combination.
- Double combination.
- Types of sanitary tee?
- Sanitary tee.
- Two-way sanitary tee.
- Sanitary cross.
- Sanitary tee with sanitary opening.
- Sanitary cross with sanitary opening.
- Figure five double fixture fitting.
- Types of test tee?
- Test tee less plug.
2. Test tee.
- Types of adapters?
- Tapped adapter.
2. Adapter.
- Types of vented closet tees?
- Vented closet tee.
- Vented closet cross.
- Vented closet cross with 2” side opening.
- 4” no-hub prison fitting.
- 10” closet fitting.
- Figure six.
7 Figure eight. - Closet fitting with 2” inlets.
- Started fittings.
- Types of quarter bend?
- Quarter bend.
- Long quarter bend.
- Tapped quarter bend.
- Quarter bend with side opening.
- Quarter bend with heel opening.
- Double quarter bend.
- Extended quarter bend with low heel outlet.
- Types of Wye?
- Wye.
- Double wye.
- Upright wye.
- Tapped wye.
- Tapped double wye.
- Types of sanitary tapped tee?
- Sanitary tapped tee.
- Extended sanitary tapped tee.
- Sanitary tapped cross.
- Extended sanitary tapped cross.
- Double vertical sanitary tapped tee.
- Horizontal twin tapped tee.
- Figure one.
- Types of vented tub wye?
- Vented tub wye.
- 45* vented tub wye.
- Vented tub wye right or left hand.
- Types of closet collars?
- Notched closet collar.
2. Slotted closet collar.
- Types of short sweep?
- Short sweep.
2. Extended short sweep.
- Types of reducer?
- Increaser-reducer.
2. Short reducer.
- Types of vent cross over?
- 2” vent cross over, plane.
- 2” vent cross over, double.
- 2” vent cross over with left/right hand inlet.
- What are requirements for lead free solder,fittings and pipe?
- Solder less than 0.2% lead.
- Fittings less than 0.3% lead.
- Pipe less than 3% lead.
- Types of closet bend?
- Less collar.
- Tapped closet bend with southern code brass plug.
- Hub-end closet bend, low hub.
- Types of plugs?
- Blind plug.
2. Tapped ferule less brass plug.