1st CRO Board Questions Flashcards

1
Q

How to place turbine on gear?

A

Oil temp satisfied, generator properly line up, take dogleg out of pull to lock, verify it starts on slow speed for 10 seconds then switches to high speed, check eccentricity on ATSI display (3mills is max)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How to establish steam seals?

A

Line up either main steam or aux steam, Gland steam exhauster in service, BFPT on gear, exhaust trunks open, make sure regulator is closed before opening block valve, self sealing at 40% load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How do we control steam temps and where are they regulated at?

A

Sprays primarily regulate superheat temps while the tilts regulate the reheater temps.

Superheat sprays go into the division panels

Reheat sprays go into the cold reheat going into the radiant reheat bypass header

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Name the runbacks

A

Loss of ID/FD
Loss of PA fan
Loss of BFP
Loss of stator coolant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Describe a rundown, run up, and run back

A

Run up/Run down- These will run the unit up or down until the error clears

Runback- Brings the unit down to a safe load that it can operate at without that piece of equipment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

List the run ups and downs

A

Air, Fuel, Throttle pressure, Feedwater, PA pressure, Furnace pressure, Drum level, Hot well level, DA level, Condensate flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the difference in single element and 3 element

A

Single element mode is use during start up. The drum is only looking at the drum level to determine how much water needs to go to the drum.

3 element mode is used during normal operation. The drum instrumentation looks at steam flow, feedwater, and drum level to determine makeup to the drum.

Switches from single element to 3 element at 12% steam flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the purpose of biasing the boiler controls

A

Bias adjustments are made when abnormal operating conditions arise causing one piece of equipment to carry more or less load than the others

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Items needed for prewarming the turbine

A

Steam conditions met
SALI chart approved

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Different types of boiler hydros

A

Static hydro puts the water at drum level height to test waterwalls

Pressure hydro uses the BFP or condensate pump to pressurize the tubes. Uses the sprays to fill all parts of the boiler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What’s the telltale for when cold filling the boiler?

A

To tell if the cold filling is leaking or not, BFV-52 is located in the basement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Explain the turbine trip bypass

A

When enabled, if the turbine trips it will take the boiler with it. If bypassed, (during startup) and the turbine trips for some reason, you wont lose the boiler. Automatically enables after starting the 2nd feeder

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When do we de-energize the precip?

A

When the exit gas temp gets below 180°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the purpose of the scanner air fans?

A

Provide cooling air to each of the flame scanners in the furnace.

Scanner air fans will auto start when furnace DP drops below 4.5” and stop when furnace DP gets to 24”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the purpose of the ignitor air fans?

A

Ensure a constant flow of cooling air around each ignitor in the boiler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the purpose of the roof enclosure fans?

A

Maintains approximately 2” above furnace operating pressure to prevent and accumulation of fly ash within the roof enclosure and leakage of hot flue gases through the furnace roof.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

When do we put precip blowers in service?

A

The heater blower system is placed in service approximately 8 hours prior to energizing the precipitators

The fly ash blower is placed in service when the system startup sequence is initiated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Ramp rate

A

75° an hour
200° max an hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Interrupt switches on fans

A

The break away regulating lever is spring loaded and will break away in case the internal regulating assembly cannot follow the regulating impulses given by the external servo motor. This will prevent any damage to the internal components. The regulating lever is located on the fans beck drive blade positioner, These are associated with both the ID and the FD fan blades

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Purpose of the 02 controllers and what page they are on

A

02 control is on air flow master page. Controls excess 02, the setpoint is 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Flow path of cold filling the boiler

A

Line comes off condensate header after gland steam condenser to CDV-61, then to regulator valve BFV-41, and another block valve BFV-23 it ties into a 16” header to the HP heaters then to the economizer inlet header

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is the process of burning out the silo’s?

A

@100 tons- lower coal air temp setpoint to 130°
@50 tons- lower feeder speed to 40-60 TPH
Place hot air damper in manual with cold air in auto, lower coal air temp to 100°-120°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Normal and high throttle pressure

A

Normal-2400
High- 2525

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What are the 3 trip devices on the turbine?

A
  • ETD Electronic trip device
  • PTR primary trip relays
  • ETR Electronic trip relays
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
What chemistry levels are we looking for in the Hotwell, DA, and Boiler?
Hotwell-ph, millipores, hardness, DO DA-DO, millipores, hardness Boiler-hardness, sodium, silica, conductivity, ph
26
How long does it take to fill the boiler and how much water does it hold?
86,000 gallons and it takes 1.5 to 2 hours to fill
27
What is the purpose of the backpass drains?
Remove condensate Normal startup they will be two turns opened Hot turbine/ cold boiler conditions they will be wide open to help match up steam temps
28
At what point is the turbine self sealing?
40% load
29
What is the flow path from the economizer to the condenser?
Economizer inlet, collector drum, BWCP, lower drum, water wall, steam drum, roof SH, BP SH, SH division panels, vertical platen SH, Front pendant SH, HP turbine, Cold reheat, Front pendant RH, Rear pendant RH, IP, LP turbine, condenser
30
When do we start the APH?
When starting the ID/FD fans
31
When do we shut down the APH?
Air heater inlet temp 400°. It helps cool the boiler down faster
32
How are safeties set up on the boiler?
Staggered because of pressure drop throughout the boiler and to maintain flow to the next component
33
If you have a sharp increase in feedwater but steam flow stays the same what is this an indication of?
Tube leak
34
What does BCS and BMS stand for?
BCS- Boiler control system, controls everything on the boiler BMS- Burner Management System, only controls fuel
35
What are the tracking lights on controllers?
It means it is watching a different controller upstream of that controller. Allows seamless transfer from one controller to the next
36
If the boiler trips what are the options for getting it back faster?
Save steam by dropping load (30%), bottle up your turbine, try to get a coal prelight permissive, once you hit 800psi/800° just bring it down because the steam will be saturated
37
When a master fuel trip occurs what happens to airflow master?
Stays in auto and the controls will hold where they’re at for 5 minutes
38
How is water circulated in the motor cavity cooler heat exchanger?
Water comes out the motor bottom and back in the top of the motor
39
What boiler feed pump tests do we perform and why?
LP and HP stop valves (Daily), at low load can’t test HP ETD test (weekly) emergency trip device, Must test one at a time. Need both in at a time to cause an actual trip Oil pump tests (weekly) Reduced speed over speed trip test (yearly) We do these to prevent silica buildup on stem
40
What is the startup process of the Boiler Feed Pump?
Turbine on gear All drains opened except high pressure above seat drain Oil Pumps on Vacuum established Warmed for 30 minutes Manually roll to 1500 RPM Line up with the deviation meter on mark 6 Push both controllers in auto Control setpoint from feedwater master set at -2
41
What are the permissives for resetting a boiler feed pump?
Exhaust trunk open Suction valve open Suction pressure Control valve closed (V1)
42
What are the boiler feed pump suction drains for?
Keeps the suction line warm while not in use
43
List the boiler feed pump trips
Vibration Exhaust pressure Push button DA level low Oil pressure low Oil temp HiHi Zero speed
44
What is a high oil temp on boiler feed pumps and turbine?
135° on BFP 130° is the high temp on MTLO
45
What is the purpose of oil pumps on the boiler feed pumps?
Main oil pumps- 2 stages, HP and LP, HP control valves and stop valves. LP is for lubrication Emergency pump is for lubrication while bringing it down HP can also supply lubrication if LP was to go out.
46
What do we use to control NoX?
Neural net and SOFA
47
What Ph do we maintain boiler water at?
9.2 or so
48
When can we line the air up to dry out the reheater?
When the temperature gets down to 300° on the cold and hot reheat on pi
49
When can we drain the boiler?
200° at the BWCP suction manifold
50
What do you need to do when breaking vacuum on the turbine?
Watch the mark 6 and when the vacuum decays shut off steam seals
51
After shutting unit down when can you start making up water with cold fill?
When the drum pressure gets below 600lbs
52
Where does the high BFP oil DP come in?
15 psi
53
How to break vacuum in a normal situation
- Take turbine off, get it on gear - Pull to lock the standby vacuum pump - Put the running vacuum pump in off (dry out) - Open the vacuum breaker, monitor back pressure - Let it run up to 10” or 15” of back pressure, then take seals off to cool turbine
54
What temperature does the bowl mill automatically inert?
170°
55
What temperature will the hot air gate automatically close on the bowl mill?
180°
56
What thrust bearing temperature does a bowl mill get a high temp alarm in?
170°
57
What bowl mill temp does the feeder speed cut back to minimum?
Alarms at 170° The feeder goes to minimum at 190°
58
What is something to monitor if you’re bringing the unit up or down?
Need to watch the APH sump for excess steam going into the fan room
59
What is NOX and how do we control it?
NOX is a byproduct of combustion. We control it using the sofa dampers and neural net.
60
What emissions do we monitor?
So2,Co2,opacity, and NOX
61
What’s the difference in a process alarm and a system alarm?
Process alarm is a normal alarm in the process that can be cleared from the alarm screen. A system alarm is an alarm in the computer system that has to be dug into to be cleared.
62
What are some important pressures on the condensate filter?
When the DP gets to 35 for 60 seconds, the filter will take itself out of service The maximum DP it is designed for is 50
63
What chemistry setpoints are watched before rolling the turbine?
DO has to be less than 100 Silica has to be less than 20
64
How much oil pressure is on the turbine and BFP?
14 on the turbine lube oil and 20 on the feed pump lube oil
65
What safeties do we have on the boiler?
- Boiler Safety (8)- 2990-3080 psi - Main Steam Safety (4)- 2755-2765psi - Cold reheat Safety (10)- 650-720psi - Hot Reheat Safety (4)- 650-655
66