How to place turbine on gear?
Oil temp satisfied, generator properly line up, take dogleg out of pull to lock, verify it starts on slow speed for 10 seconds then switches to high speed, check eccentricity on ATSI display (3mills is max)
How to establish steam seals?
Line up either main steam or aux steam, Gland steam exhauster in service, BFPT on gear, exhaust trunks open, make sure regulator is closed before opening block valve, self sealing at 40% load
How do we control steam temps and where are they regulated at?
Sprays primarily regulate superheat temps while the tilts regulate the reheater temps.
Superheat sprays go into the division panels
Reheat sprays go into the cold reheat going into the radiant reheat bypass header
Name the runbacks
Loss of ID/FD
Loss of PA fan
Loss of BFP
Loss of stator coolant
Describe a rundown, run up, and run back
Run up/Run down- These will run the unit up or down until the error clears
Runback- Brings the unit down to a safe load that it can operate at without that piece of equipment
List the run ups and downs
Air, Fuel, Throttle pressure, Feedwater, PA pressure, Furnace pressure, Drum level, Hot well level, DA level, Condensate flow
What is the difference in single element and 3 element
Single element mode is use during start up. The drum is only looking at the drum level to determine how much water needs to go to the drum.
3 element mode is used during normal operation. The drum instrumentation looks at steam flow, feedwater, and drum level to determine makeup to the drum.
Switches from single element to 3 element at 12% steam flow
What is the purpose of biasing the boiler controls
Bias adjustments are made when abnormal operating conditions arise causing one piece of equipment to carry more or less load than the others
Items needed for prewarming the turbine
Steam conditions met
SALI chart approved
Different types of boiler hydros
Static hydro puts the water at drum level height to test waterwalls
Pressure hydro uses the BFP or condensate pump to pressurize the tubes. Uses the sprays to fill all parts of the boiler
What’s the telltale for when cold filling the boiler?
To tell if the cold filling is leaking or not, BFV-52 is located in the basement
Explain the turbine trip bypass
When enabled, if the turbine trips it will take the boiler with it. If bypassed, (during startup) and the turbine trips for some reason, you wont lose the boiler. Automatically enables after starting the 2nd feeder
When do we de-energize the precip?
When the exit gas temp gets below 180°
What is the purpose of the scanner air fans?
Provide cooling air to each of the flame scanners in the furnace.
Scanner air fans will auto start when furnace DP drops below 4.5” and stop when furnace DP gets to 24”
What is the purpose of the ignitor air fans?
Ensure a constant flow of cooling air around each ignitor in the boiler
What is the purpose of the roof enclosure fans?
Maintains approximately 2” above furnace operating pressure to prevent and accumulation of fly ash within the roof enclosure and leakage of hot flue gases through the furnace roof.
When do we put precip blowers in service?
The heater blower system is placed in service approximately 8 hours prior to energizing the precipitators
The fly ash blower is placed in service when the system startup sequence is initiated
Ramp rate
75° an hour
200° max an hour
Interrupt switches on fans
The break away regulating lever is spring loaded and will break away in case the internal regulating assembly cannot follow the regulating impulses given by the external servo motor. This will prevent any damage to the internal components. The regulating lever is located on the fans beck drive blade positioner, These are associated with both the ID and the FD fan blades
Purpose of the 02 controllers and what page they are on
02 control is on air flow master page. Controls excess 02, the setpoint is 3
Flow path of cold filling the boiler
Line comes off condensate header after gland steam condenser to CDV-61, then to regulator valve BFV-41, and another block valve BFV-23 it ties into a 16” header to the HP heaters then to the economizer inlet header
What is the process of burning out the silo’s?
@100 tons- lower coal air temp setpoint to 130°
@50 tons- lower feeder speed to 40-60 TPH
Place hot air damper in manual with cold air in auto, lower coal air temp to 100°-120°
Normal and high throttle pressure
Normal-2400
High- 2525
What are the 3 trip devices on the turbine?
- ETD Electronic trip device
- PTR primary trip relays
- ETR Electronic trip relays