1.1 How temperature affects the rate of milk hydrolysis Flashcards

You may prefer our related Brainscape-certified flashcards:
1
Q

What is casein?

A

A milk protein which makes milk white and opaque
When casein is digested the milk becomes clear

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the method?

A
  1. Using a glass rod, stir milk to ensure the milk powder has dissolved
  2. Add 10cm^3 of milk to a 50cm^3 beaker with a 10cm^3 syringe
  3. Add 1cm^3 of pH buffer to beaker and stir with a glass rod
  4. Place beaker in water bath for 5 minutes for the milk to reach the correct temperature
  5. After 5 mins, before removing from water bath, add 1cm^3 of enzyme (protease) and start stop watch at the same time
  6. Place your beaker of milk on a laminated cross on your desk
  7. Record the exact time the cross could be first seen
  8. Rinse equipment and repeat with the other water bath temperatures
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the risk of using an enzyme and what is the control measure?

A

Risk - enzymes can irritate the eyes/skin
control measure - wear eye protection and lab coats, wash off the skin with soap and plenty of water, wipe up the solution spills with a damp paper towel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the risk of using a water bath and what is the control measure?

A

Risk- hot water can scale skin
Control measure- use tongs when removing test tubes from water bath, if scalded run under cold water and seek first aid immediately

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the risk of using glassware and what is the control measure?

A

Risk- if glass smashes you could cut yourself
Control measure- keep all glassware in the centre of the desk at all times and place test tubes in a test tube rack, if injured seek first aid immediately

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Describe the limitations of this procedure and the improvements you would carry out to give more valid/ reliable data

A
  1. The different test tubes were left in the water bath for different times - to improve only out a test tube in when finished with one to take out at same time
  2. The temperature decreased when taking the test tube out of the water bath to the station - to improve, work straight away next to the water bath
  3. Lid of the water bath was constantly taken on and off so water may not of been at required temperature - to improve only remove lid when removing or inserting test tubes and place back on quickly
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Give 2 control variables

A
  1. Concentration of substrate
  2. pH - used a buffer to keep it consistent
How well did you know this?
1
Not at all
2
3
4
5
Perfectly