1. Introduction Quiz Flashcards

1
Q

What section of NFPA 70 (NEC) specifically covers fire alarm systems?

A

Article 760

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Individuals who perform those procedures, adjustments, replacement of components, system programming, and maintenance as described in the manufacturers service instructions that can affect any aspect of the performance of the system.

A

Service Personnel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What chapter of NFPA 72 covers emergency control functions and devices?

A

Chapter 21

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Any alarm that occurs that is not the result of a potentially hazardous condition is known as a _____ _____.

A

Unwanted Alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What chapter of NFPA 72 covers supervising station requirements?

A

Chapter 26

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Who might be an Authority Having Jurisdiction (AHJ) on a construction project for a new multi-story building? (Name 3)

A

Building Owner, Fire Chief in the Jurisdiction, County Electrical Inspector

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A signal indicating a concentration of carbon monoxide at or above the alarm threshold that could pose a risk to life safety requires ______ ?

A

Immediate Action

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A combination system is part of the fire alarm system that?

A

Is shared with non-fire signaling equipment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A fire alarm device that has a FM (Factory Mutual) sticker on it is?

A

Labeled and Listed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

An unwanted activation of a signaling system or alarm initiation device in response to a stimulus or condition that is not the result of a potentially hazardous condition is a ____ ?

A

Nuisance Alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Individuals responsible for the development of fire alarm signaling system plans and specifications in accordance with NFPA 72

A

System Designer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The word SHALL in code indicates a mandatory requirement

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Individuals who conducts a visual examination of a system or portion thereof to verify that it appears to be in operating condition, in proper location, and is free of physical damage or conditions that impair operation.

A

Inspection Personnel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

An unwanted activation of an alarm initiating device caused by a person acting with malice is known as ____ ?

A

Malicious Alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

All material in a standard is mandatory

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The Annex A material in NFPA 72 contains mandatory requirements that support the main text of the code

A

False

17
Q

Individuals who perform procedures used to determine the status of a system as intended by conducting acceptance, reacceptance, or periodic physical checks on system

A

Testing Personnel

18
Q

What chapter of NFPA 72 covers the requirements of inspection of mass notification systems?

A

Chapter 14